9 INSTALL BATTERIES / INSTALL LEVER
Install batteries provided and fit battery cover.
See diagram.
Install inside lever onto spindle according to the hand of door. Lever will be secure when pushed firmly onto spindle with a
"click".
OPERATIONAL CHECK
Before closing door check the operation of you lock:
* Test operation of the lock by depressing internal lever to retract the latch.
* Test operation of the lock by entering Master Code and depressing front lever to retract the latch.
* If either fails, check installation of lock again.
SPECIAL INSTRUCTION
Remote release option
Cables are provided for the REM 1 and
REM 2 terminals on the circuit board. (Fig 1).
REM 1
is for connection to a reception desk push button or a
door intercom system. Pressing the button will cause the Blue
light to flash on the lock and release the lock for the pre-set
time.
REM 2
is for connection to a fire alarm system so as to
release a door in an emergency. This allows rooms, wards,
offices to be easily checked to ensure that no person is
trapped or overlooked during an emergency or a practice fire
drill. When activated REM 2 will maintain the unlocked
condition for 30 minutes, and the Red LED will flash and
BLEEP during this time. The lock will automatically lock again
after 30 minutes. If necessary Program 11 can be used to
re-lock before the end of the 30 minutes.
REM 1 and REM 2 do not require additional power. They are
normally open contract requiring a mementary or maintained
signal to close.
THE METHOD OF CHANGING LOCK HAND, RH TO LH
1
Turn key clockwise and depress lever
catch with tool provided, and pull off lever.