4/14/2016
D014465 CR1400 CR1000 CR2300 CR2600 CR3600 CR44X5 CR8000 CR900FD CR6000 CR5000 T500 Client Version ICD
Page 34 of 106
© 2013-2016 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Reg Setting Name
Default (Hex)
Comment
1C
Serial Baud Rate
1C200
(#115200)
All standard baud rates from 300 baud to 115200 baud
12C (#300)
4B0 (#1200)
960 (#2400)
12C0 (#4800)
2580 (#9600)
4B00 (#19200)
9600 (#38400)
E100 (#57600)
1C200 (#115200)
Persistence: Protected
Keywords: #SerialComm
1D
Serial Stop Bits
1
1: Send 1 Stop Bit
2: Send 2 Stop Bits
Keywords: #SerialComm
1E
Serial Data Bits
8
7: 7 Data Bits
8: 8 Data Bits
Keywords: #SerialComm
1F
Serial Flow Control
0
0: Disabled
1: Hardware
Note: Undefined behavior will result if this setting is enabled
when Output Good Read on RTS (0x02F1) is enabled.
Keywords: #SerialComm
22
Serial Parity
0
0: None
1: Odd
2: Even
Keywords: #SerialComm
26
Beep Volume (percent) 64
(#100)
Valid Range: 0 to 64 (#100) Percent
This is the current percentage of full volume potential.
Keywords: #Beep
29
PDF417 Symbology
1
0: Disabled
1: Enabled
Note: This register has no effect on a CR900FD without the
proper 2D barcode decoding license.
Keywords: #PDF417