Code Blue
•
259 Hedcor Street
•
Holland, MI 49423 USA
•
800.205.7186
•
www.codeblue.com
GU-153-H
page 9 of 26
Public Address System
Administrator Guide
5 Installation & System Setup
This section covers the following units:
• CB 1 Series with Public Address, including the 360° PAS Retrofit Kit
• CB 5-s with Public Address
• CB 2-e with Public Address
• WM-180°
5.1 CB 1 Series with Public Address, including 360° PAS Retrofit Kit
The following models are covered in the installation instructions for CB 1 Series with
Public Address or the 360° PAS Retrofit Kit:
• CB 1-e
• CB 1-s
5.1.1 Tools Required
• Ladder – to reach the top of the unit.
• Security bit – to secure the PAS top to the adapter ring.
• 6mm Allen wrench – to secure the PAS adapter ring to the top of the unit.
• 3/8” socket set - to mount the mounting plate containing the new toroid
transformer.
5.1.2 Before You Begin
• Remove 120V AC power from the unit.
5.1.3 Install Adapter Ring
5.1.3.1 Remove the existing dome top assembly. Disconnect the red/black and
yellow/yellow wiring harnesses connected to the beacon/strobe mount-
ed in the dome top assembly.
5.1.3.2 Place the adapter ring on top of the bollard and tighten the three Allen
set screws to hold in place (see
Figure 2
on Page 12).
5.1.4 Transformer Installation
Install new toroid transformer.
NOTE: Skip this section if you ordered a CB 1 Series with Public Address
as a complete unit.
5.1.4.1 Remove lower access door on the CB 1 bollard.
5.1.4.2 Remove the existing 120V AC step down transformer.
5.1.4.3 Install toroid transformer with mounting plate using supplied hardware
(see
Figure 1
on Page 10).
5.1.4.4 Connect incoming 120V AC wiring to the transformer using the junc-
tion box on mounting plate. Refer to included wiring diagram for wiring