Feature Bank 3 - Output Control
1 - Lock / Unlock Timing:
Controls the timing of the BLUE and GREEN lock output
wires.
1 Sec. - Single 1 second lock pulse, single 1 second unlock pulse.
3.5 Sec. - Single 3.5 second lock pulse, single 3.5 second unlock pulse.
1 Sec. Lock, 2x Unlock - Single 1 second lock pulse, double 1 second unlock
pulse.
30 Sec. Lock, 2x Unlock - Single 30 second lock pulse, double 1 second
unlock pulse.
2x Lock, 1 Sec. Unlock - Double 1 second lock pulse, single 1 second unlock
pulse.
0.5 Sec. Pulse - Single 0.5 second lock pulse, single 0.5 second unlock pulse.
2 - Factory Disarm, Lt Green/Black Output:
Controls the timing of the LT. GREEN/
BLACK factory disarm output.
Factory Disarm - Single 1 second pulse with unlock and remote start activation.
2nd Unlock - Same output timing as unlock with 2nd press of unlock only.
Factory Disarm 2x 500mS - Double 500mS second pulse with unlock and
remote start activation.
Factory Disarm 350mS - Single 350mS second pulse with unlock and remote
start activation.
Factory Disarm 500mS - Single 500mS second pulse with unlock and remote
start activation.
Factory Disarm w/ Unlock Timing – Uses the timing option set for Unlock in
Bank 3, Feature 1.
16 - Dome Light Delay, Preset Time or Programmable:
The system can be
programmed to delay arming after the lock button is pressed based on preset delay
times or a customizable delay time.
OFF/Program Custom Time -
There will be NO delay unless a custom
delay time has been learned. If a time has been learned, the system will add 2
seconds to the end of the programmed time before arming.
15 Seconds -
The system will wait 15 seconds before arming.
30 Seconds -
The system will wait 30 seconds before arming.
45 Seconds -
The system will wait 45 seconds before arming.
60 Seconds -
The system will wait 60 seconds before arming.
120 Seconds -
The system will wait 120 seconds before arming.