background image

Page 3 of 12

RED WIRE

PIN 1

BLUE WIRE

PIN 3

BLACK WIRE

PIN 5

WHITE WIRE

PIN 4

1.5”

 

Figure 3

Figure 2

Figure 4

Flash Pattern Selection:

To select a flash pattern, apply power to the RED or WHITE or both RED and WHITE wires. (WHITE wire is for dual color only) Momentarily 

touch the BLUE wire to the BLACK wire (ground) for less than 1 second to advance to the next pattern. To go back to the previous pattern, 

momentarily touch the BLUE wire to the BLACK wire for approximately 2 - 3 seconds. To force the flash pattern to STEADY, momentarily 

touch the BLUE wire to the BLACK wire for approximately 5 seconds. When Vacuum-Magnet Mount is being used, the BLUE wire is 

connected to ground via the momentary switch on the cigarette plug as shown in FIGURE 2. For more detail about flash patterns, please see 

the SINGLE and DUAL COLOR FLASH PATTERN TABLES below.

Flash Pattern Synchronization:

The permanent mount microbars sync with compatible Code 3 products via the yellow wire:

Step 1.  

Determine the desired style of flash pattern for each unit and set each unit individually (without the yellow wires connected together) 

to avoid confusion. It is also strongly recommended that the same style of flash pattern be used on all units to produce the most effective 

warning pattern. (NOTE: Phases A and B for each style of flash pattern in the table denote the relative timing between units connected in a 

synchronizing installation. To operate simultaneously, each unit must be set to the same phase (A + A or B + B); to operate alternately, units 

must be set to have the opposite phase (A + B or B + A)).

Step 2.  

Connect the yellow sync wires together and check that the units are flashing in a synchronized manner as expected. If a pattern 

on one unit appears incorrect, the blue pattern select wire can be used to cycle forward or backward on that individual unit until the correct 

pattern is selected. Note: This will only change the pattern in the one unit and will not affect the other units connected to the yellow sync wire.

Step 3.  

If the yellow wire is unused, leave unconnected and insulated.

Dimming Feature:

To activate the dimming feature of this mircobar, attach the BLUE wire to the RED wire (+BATT).

Summary of Contents for C5550 Series

Page 1: ...s maximized and the controls are placed within convenient reach of the operator so that they can operate the system without losing eye contact with the roadway 5 Do not install this product or route a...

Page 2: ...scratching the paint on the vehicle After placement the microbar should adhere firmly to the surface If the unit slides or moves easily a proper installation has not been obtained To release the vacu...

Page 3: ...desired style of flash pattern for each unit and set each unit individually without the yellow wires connected together to avoid confusion It is also strongly recommended that the same style of flash...

Page 4: ...onnections and splices to protect these points from corrosion and loss of conductivity 5 Ground termination should only be made to substantial chassis components preferably directly to the vehicle bat...

Page 5: ...Split 75 Y 10 Double 120 Y A Class 1A Class 1A Class 1A Class 1A Class 1 Class 1 Class 1 Class 1 11 Double 120 Y B Class 1A Class 1A Class 1A Class 1A Class 1 Class 1 Class 1 Class 1 12 Double Altern...

Page 6: ...5 Y A 7 15 Single Color 2 375 Y B 8 8 16 Single Color 1 then 2 375 Y A 9 9 17 Single Color 1 then 2 375 Y B 10 10 18 Single Split Alternating Color 1 then 2 375 Y 11 19 Double Color 1 75 Y A Class 1A...

Page 7: ...E 26 47 Quad Color 1 75 Y B Class 1A Class 1A Class 1A Class 1A Class E Class E Class E 48 Quad Split Color 1 2 75 Y A 49 Quad Split Color 1 2 75 Y B 25 50 Quad Color 2 75 Y A Class 1A Class 1A Class...

Page 8: ...73 Quad Diagonal Color 1 150 Y B 74 Quad Diagonal Split Alternating Color 1 then 2 150 Y A 75 Quad Diagonal Split Alternating Color 1 then 2 150 Y B 39 76 Quad Diagonal Color 2 150 Y A 40 77 Quad Dia...

Page 9: ...Page 9 of 12 Notes...

Page 10: ...Page 10 of 12 Notes...

Page 11: ...Page 11 of 12 Notes...

Page 12: ...ISCLAIMED EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW ORAL STATEMENTS OR REPRESENTATIONS ABOUT THE PRODUCT DO NOT CONSTITUTE WARRANTIES Remedies and Limitation of Liability MANUFACTURER S SOLE L...