32
LINUS10-C
5. SPECIFICATION
Output
RMS output power*
(20 Hz - 20 kHz, THD < 0.01%)
(all channels driven)
1400 W @ 8 Ω
2500 W @ 4 Ω
3100 W @ 2.7 Ω
3700 W @ 2 Ω
Peak output power*
(20 Hz - 20 kHz, 6 dB Crest Factor)
(all channels driven)
3200 W pk @ 8 Ω
5200 W pk @ 4 Ω
5800 W pk @ 2.7 Ω
5000 W pk @ 2 Ω
Maximum output voltage*
+/- 170 V pk
Maximum output current*
+/- 52 A pk
Damping factor
(8 Ω load, 1 kHz and below)
> 800
Minimum output load
2 Ω nom
Power output connections
2 x Neutrik NL4 speakON®
1 x Neutrik NL8 speakON®
Thermal
Operating temperature
+5º C to +55º C
41º F to 131º F
Thermal output
(BTU/h)
696.08 = Idle
1910.80 = 20%
3739.71 = 50%
6776.51 = 100%
Thermal output
(kWh)
0.204 = Idle
0.560 = 20%
1.096 = 50%
1.986 = 100%
Cooling
2 x thermally controlled fans
Hot air expelled at rear