12
Part 6 Gas Conversion
Gas Regulator
NOTE:
The gas regulator supplied is convertible between
Natural Gas and LP Gas, but it’s outlet pressure is
fixed ex-factory and is NOT to be adjusted.
- NAT Gas / LPG / Butane Only.
- Town Gas Only.
1. Remove slotted cap from regulator.
2. Turn ‘On’ gas supply and appliance.
3. Adjust pressure adjusting screw to achieve
correct burner operating pressure.
NOTE:
Measure operating pressure at manifold test point
with two burners operating at 'High Flame' setting.
4. Screw cap nut back onto regulator.
Gas Type Identification Label
1. On completion of gas conversion, replace gas
type identification label located at:-
- Rear of appliance, above gas connection.
- Beside the rating plate.
Commissioning
Before leaving the installation;
1. Check all gas connections for leakage using
soapy water or other gas detecting equipment.
2. Carry out a ‘Commissioning’ check of appliance
as shown in Installation Section of this manual.
3. Ensure any adjustments done to components
that have adjustments / settings paint sealed
are to be re-sealed.
NOTE: If it is not possible to get appliance to operate
correctly, shut ‘Off’ the gas supply and contact
supplier of this appliance.
NOTE, Pin rotated
for Natural Gas
NOTE, Pin rotated
for LPG
Pressure Adjusting
Screw
Cap Nut
WARNING:
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.