Oven (Cont’d)
Fault
Possible Cause
Remedy
Set temperature not reached
Gas supply fluctuating.
Gas valve not set up correctly.
Thermostat out of calibration.
Gas control faulty.
Check supply for correct pressure.
Call service provider.
Call service provider.
Call service provider.
Oven too hot
Gas valve not set up correctly.
Thermostat out of calibration.
Call service provider.
Call service provider.
Door does not close
Tray in way of door.
Door ball catch setting incorrect.
Correctly position tray in rack.
Call service provider.