background image

9

Nothing 

comes close to a Cobra

8

English

Connecting Cables (not included)

Power wire and wiring are very important to the performance
of the inverter. Because the inverter has a low voltage,
high current input, low resistance wiring is essential
between the battery and inverter. This is so it can deliver
the maximum amount of energy to the load. 

Use only copper wire. Aluminum wire has about 

1

3

more

resistance than copper wire of the same size, plus it is
difficult to make good, low-resistance connections to
aluminum wire.

We recommend two #4 AWG copper cables (90°C
insulation rating) as the minimum size for connections
between the battery and inverter.

Keep the cable length as short as possible, no more
than 4 ft. (1.5 meters). This will keep the voltage 
drop to a minimum.

If the cable has too much voltage drop, the inverter 
may shut down when drawing higher currents because
voltage at the inverter may drop below 10 volts. If you
must use longer cables, choose thicker cables, such as
#2 AWG, and trim the ends of the cable to fit the terminals.

To Connect the Cables Between the Inverter 
and the Battery:

1. Turn the On/Off Switch on the inverter to the Off

position. If the power source is a DC power supply,
switch it Off as well.

2. On the end of the cable that connects to the inverter,

strip back the insulation about 

1

2

inch (1.25 cm),

exposing the bare copper conductor.

3. Connect cables to the Power Input Terminals on right

side panel of the inverter. The red terminals are positive
(+) and the black terminals are negative (-). Insert the
bare ends of the cables into the terminals and tighten
the screws to clamp the wires safely.

4. Connect cables to the power source:

a. Connect each cable from the Negative (Black)

Terminals of inverter to the Negative Terminal
of the power source. Make a secure connection. 

b. Connect each cable from the Positive (Red)

Terminals of the inverter to the Positive Terminal
of the power source (the battery’s main fuse or 
the battery selector switch, if you are using one).
Make a secure connection.

Continued...

Connecting Cables

Connecting Cables

Installation

Installation

On/Off Switch to Off

Strip the Insulation

Insert Bare Cables

Connect Cables

Summary of Contents for CPI-2500

Page 1: ...t understand its many features please refer to this owner s manual If you require further assistance after reading this manual Cobra Electronics offers the following customer assistance services For A...

Page 2: ...n Our Thanks to You A1 Customer Assistance A1 Controls and Indicators A2 Product Features A2 Important Safety Information 1 Quick Evaluation Before Installation 4 Installation Installation Requirement...

Page 3: ...unit or other equipment WARNING Statements identify conditions that could result in personal injury or loss of life General Precautions 1 Never install the inverter in a boat s engine compartment whe...

Page 4: ...attery packs used in hand power tools These chargers have a WARNING label stating that dangerous voltages are present at the battery terminals This problem does not occur with the vast majority of bat...

Page 5: ...about 1 2 inch 1 25 cm back from the end exposing the bare copper The other end of the cable which connects to the power source must be terminated with a lug or other connector that provides a secure...

Page 6: ...wires cables CAUTION To avoid fire do not cover or obstruct ventilation openings Do not install inverter in a zero clearance compartment Overheating may result CAUTION The inverter must only be conne...

Page 7: ...as 2 AWG and trim the ends of the cable to fit the terminals To Connect the Cables Between the Inverter and the Battery 1 Turn the On Off Switch on the inverter to the Off position If the power source...

Page 8: ...battery as possible We recommend a Buss Fuse ANL 250 or equivalent The specific fuse ampere rating should be sized to allow operation of all your DC powered equipment CAUTION Remove any jewelry watch...

Page 9: ...ill be running between battery charging cycles 3 Calculate the total watt hours of energy consumption power x operating time using the average power consumption and the total estimated running time in...

Page 10: ...itch the On Off Switch to Off NOTE The On Off Switch turns the control circuit in the inverter On and Off It does not disconnect power from the inverter When the switch is in the Off position the inve...

Page 11: ...he battery It will not indicate the current drawn by other loads also connected to the battery For long term operation the current meter should remain in the middle of the bar graph Operating Limits P...

Page 12: ...increases as the load increases The unit is completely insulated in input and output for added safety 18 English Troubleshooting Guide Operation Problem Symptom Low output voltage No output voltage No...

Page 13: ...ing you of the repair charge or replacement charge If you have any questions please call 773 889 3087 for assistance Maintenance and Product Service Customer Assistance 20 English Limited 1 Year Warra...

Page 14: ...707 USA To order online please visit our website www cobra com The Cobra line of quality products includes CB Radios microTALK Radios Radar Laser Detectors Safety Alert Traffic Warning Systems Accesso...

Reviews: