background image

5

Nothing 

comes close to a Cobra

4

English

Quick Evaluation 
Before Installation

Introduction

Quick Evaluation 
Before Installation

Introduction

Quick Evaluation Before Installation

This section provides you with basic information about 
the inverter and how to check its performance before
installation.

Be Sure to Have on Hand:

A 12 volt DC power source (such as a vehicle battery).

1. The power source must provide

between 11 and 15 volts DC and
be able to supply enough current
to run the test load. As a rough
guide, divide the wattage of the
test load by 10 to get the current
(in amperes) the power source
must deliver.

A set of cables to connect the power source to the
inverter (not included).

The cables must be as short and thick as possible in
order to reduce the voltage drop between the power
source and the inverter when drawing current from 
the power source. 

If the cable suffers an excessive voltage drop, the inverter
may shut down when drawing higher currents because
the voltage at the inverter dropped below 10 volts. 

#4 AWG stranded copper cable is recommended. 
It should be no longer than 1.5 meters (4 ft.). 

The end of the cable that connects to the inverter must
have its insulation stripped off for about 

1

2

inch (1.25 cm)

back from the end, exposing the bare copper. 

The other end of the cable, which connects to the power
source, must be terminated with a lug or other connector
that provides a secure, low resistance connection. 

For example, if the power source is a battery, the cable
must be terminated with a battery terminal that clamps
to the post on the battery. 

A test load that can be plugged into the AC receptacle on
the inverter for short term testing at a low power level.
The following cables are recommended for testing low
power level test loads only.

Test Load 

Minimum

Power

Cable Size

100w

# 16 AWG copper

250w

# 12 AWG copper

500w

# 8 AWG copper

To Check Your Inverter’s Performance Before Installation:

1. Turn the inverter Off (see page 14

for details). If the power source is
a DC power supply, switch it Off
as well.

2. Connect cables to Power Input

Terminals (see page 8 for details).

3. Connect cables to power source

(see page 8 for details).

4. Check to make sure all

connections are secure.

5. Turn the inverter On. If the 

power source is a DC power
supply, switch it On first.

6. Plug in the test load.

The inverter should supply power 
to the load. If the inverter is not
working properly, refer to the
Troubleshooting Guide on page 18 
or Power and Protection Indicators
section on page 16.

Power Supply

Test Load

On/Off Switch to Off

Connect Terminals

Connect Power Source

On/Off Switch to On

Connect Test Load

Summary of Contents for CPI-2500

Page 1: ...t understand its many features please refer to this owner s manual If you require further assistance after reading this manual Cobra Electronics offers the following customer assistance services For A...

Page 2: ...n Our Thanks to You A1 Customer Assistance A1 Controls and Indicators A2 Product Features A2 Important Safety Information 1 Quick Evaluation Before Installation 4 Installation Installation Requirement...

Page 3: ...unit or other equipment WARNING Statements identify conditions that could result in personal injury or loss of life General Precautions 1 Never install the inverter in a boat s engine compartment whe...

Page 4: ...attery packs used in hand power tools These chargers have a WARNING label stating that dangerous voltages are present at the battery terminals This problem does not occur with the vast majority of bat...

Page 5: ...about 1 2 inch 1 25 cm back from the end exposing the bare copper The other end of the cable which connects to the power source must be terminated with a lug or other connector that provides a secure...

Page 6: ...wires cables CAUTION To avoid fire do not cover or obstruct ventilation openings Do not install inverter in a zero clearance compartment Overheating may result CAUTION The inverter must only be conne...

Page 7: ...as 2 AWG and trim the ends of the cable to fit the terminals To Connect the Cables Between the Inverter and the Battery 1 Turn the On Off Switch on the inverter to the Off position If the power source...

Page 8: ...battery as possible We recommend a Buss Fuse ANL 250 or equivalent The specific fuse ampere rating should be sized to allow operation of all your DC powered equipment CAUTION Remove any jewelry watch...

Page 9: ...ill be running between battery charging cycles 3 Calculate the total watt hours of energy consumption power x operating time using the average power consumption and the total estimated running time in...

Page 10: ...itch the On Off Switch to Off NOTE The On Off Switch turns the control circuit in the inverter On and Off It does not disconnect power from the inverter When the switch is in the Off position the inve...

Page 11: ...he battery It will not indicate the current drawn by other loads also connected to the battery For long term operation the current meter should remain in the middle of the bar graph Operating Limits P...

Page 12: ...increases as the load increases The unit is completely insulated in input and output for added safety 18 English Troubleshooting Guide Operation Problem Symptom Low output voltage No output voltage No...

Page 13: ...ing you of the repair charge or replacement charge If you have any questions please call 773 889 3087 for assistance Maintenance and Product Service Customer Assistance 20 English Limited 1 Year Warra...

Page 14: ...707 USA To order online please visit our website www cobra com The Cobra line of quality products includes CB Radios microTALK Radios Radar Laser Detectors Safety Alert Traffic Warning Systems Accesso...

Reviews: