Turning Your Inverter On or Off

Be sure to have your power inverter properly installed before
attempting to turn the unit On (see “Installation” page 6).

To Turn the Power Inverter On:

1. If a DC power supply is being used as the power

source, switch it On. 

2. On the left side panel, switch the On/Off Switch to On.

The inverter is now ready to deliver AC power to your loads.
If several loads are to be operated by the inverter, turn
them On separately, after the inverter has been turned On.
This will ensure that the inverter does not have to deliver
the starting currents required for all the loads at once.

To Turn the Power Inverter Off:

1. On the left side panel, switch the On/Off Switch to Off.

NOTE  The On/Off Switch turns the control circuit 
in the inverter On and Off. It does not disconnect
power from the inverter.

When the switch is in the Off position, the inverter 
draws no current from the battery. When it’s in the 
On position, but no power is being supplied to the
load, the inverter draws less than 500 milliamperes
from the battery. This is low current draw. It would
take more than a week to discharge a 100 ampere-
hour battery at this rate depending on the age of
the battery. 

Remote On /Off Switch (not included)

An optional Remote On/Off Switch (not included) can be
connected to the Remote Jack allowing you to turn the 
Cobra

®

CPI 2500 Inverter On or Off from a convenient location

when the inverter is installed in an out of reach location.

Power On & Off

Operation

Remote On /Off Switch

Operation

On/Off Switch to On

Remote Switch

Remote Jack

On/Off Switch to Off

Summary of Contents for CPI-2500

Page 1: ...t understand its many features please refer to this owner s manual If you require further assistance after reading this manual Cobra Electronics offers the following customer assistance services For A...

Page 2: ...n Our Thanks to You A1 Customer Assistance A1 Controls and Indicators A2 Product Features A2 Important Safety Information 1 Quick Evaluation Before Installation 4 Installation Installation Requirement...

Page 3: ...unit or other equipment WARNING Statements identify conditions that could result in personal injury or loss of life General Precautions 1 Never install the inverter in a boat s engine compartment whe...

Page 4: ...attery packs used in hand power tools These chargers have a WARNING label stating that dangerous voltages are present at the battery terminals This problem does not occur with the vast majority of bat...

Page 5: ...about 1 2 inch 1 25 cm back from the end exposing the bare copper The other end of the cable which connects to the power source must be terminated with a lug or other connector that provides a secure...

Page 6: ...wires cables CAUTION To avoid fire do not cover or obstruct ventilation openings Do not install inverter in a zero clearance compartment Overheating may result CAUTION The inverter must only be conne...

Page 7: ...as 2 AWG and trim the ends of the cable to fit the terminals To Connect the Cables Between the Inverter and the Battery 1 Turn the On Off Switch on the inverter to the Off position If the power source...

Page 8: ...battery as possible We recommend a Buss Fuse ANL 250 or equivalent The specific fuse ampere rating should be sized to allow operation of all your DC powered equipment CAUTION Remove any jewelry watch...

Page 9: ...ill be running between battery charging cycles 3 Calculate the total watt hours of energy consumption power x operating time using the average power consumption and the total estimated running time in...

Page 10: ...itch the On Off Switch to Off NOTE The On Off Switch turns the control circuit in the inverter On and Off It does not disconnect power from the inverter When the switch is in the Off position the inve...

Page 11: ...he battery It will not indicate the current drawn by other loads also connected to the battery For long term operation the current meter should remain in the middle of the bar graph Operating Limits P...

Page 12: ...increases as the load increases The unit is completely insulated in input and output for added safety 18 English Troubleshooting Guide Operation Problem Symptom Low output voltage No output voltage No...

Page 13: ...ing you of the repair charge or replacement charge If you have any questions please call 773 889 3087 for assistance Maintenance and Product Service Customer Assistance 20 English Limited 1 Year Warra...

Page 14: ...707 USA To order online please visit our website www cobra com The Cobra line of quality products includes CB Radios microTALK Radios Radar Laser Detectors Safety Alert Traffic Warning Systems Accesso...

Reviews: