Part 3  Installation 

 
 
 

c.  Input Rate of this appliance is also stated on 

the Rating Plate fitted to the inside of the  
access door and in the ‘Specifications’  
section of this manual.  The input rate should 
be checked against the available gas supply 
line capacity.  Particular note should be  

taken if the appliance is being added to an 
existing installation.
 

 

NOTE: 
It is important that adequately sized piping runs 
directly to the connection joint on the appliance, 
with as few tees and elbows as possible to give 
maximum supply volume. 
 
3.  A suitable joining compound which resists the 

breakdown action of LPG must be used on 
every gas line connection, unless compression 
fittings are used. 

 

The connection to the appliance is 

3

/

4

” BSP male. 

 

NOTE: 
A Manual Isolation Valve must be fitted to the  
individual appliance supply line. 
 
4.  Locate the appliance into its final operating 

position and using a spirit level, adjust the legs so 
that the unit is level and at the correct height. 

5.  Connect the gas supply to the appliance. 
6.  Check all gas connections for leakages using 

soapy water or other gas detecting equipment. 

7.  Check Supply Pressure is as shown in the 

‘Specifications’ section, ‘Gas Supply  
Requirements’ tables. (Measure at the ‘Supply 
Pressure Test Point’ (Upper - IN) on the front of 
the gas control valve). 

8.  Measure Main Burner Operating Pressure at  

Operating Pressure Test Point (Lower - Out) on 
the Gas Control Valve.  Adjust if required, as 
shown in the ‘Specifications’ section, ‘Gas  
Supply Requirements’ tables. 



Refer to the ‘Gas Conversion and Specifications’ 

section of this manual for further details. 

9.  Please note that the pilot flame size is factory set 

and paint sealed.  Check that the pilot covers 
the thermocouple.  If the pilot needs adjusting, 
this should be carried out by a qualified service 
agent. 

 

Clearances 

NOTE: 

Only non-combustible materials can be used in 
close proximity to this appliance. 
To facilitate easy operation, drainage and servicing 
of the fryer, a minimum of 600mm clearance should 

be maintained at the front of the appliance. 
 
Any gas burning appliance requires adequate 

clearance and ventilation for optimum and trouble-
free operation.  The following minimum installation 
clearances are to be adhered to: 

 

Assembly 

This model is delivered completely assembled.   
Ensure that the Basket Hanger has been correctly 
fitted as shown on previous page. 
Ensure that the legs are securely attached. 
 
NOTE: 
This appliance is fitted with adjustable feet to enable 
the appliance to be positioned securely and level.  
This should be carried out on completion of the gas 
connection.  Refer to the 'Gas Connection' section. 
 

Gas Connection 

NOTE: 
ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A 
QUALIFIED SERVICE PERSON. 
 
1.  COBRA Model Fryers do not require an electrical 

connection, they function totally on the gas 
supply only. 

2.  It is essential that the gas supply is correct for the 

appliance to be installed and that adequate 
supply pressure and volume are available.  The 
following checks should therefore be made 
before installation:- 
a.  The Gas Type the appliance has been  

supplied for is shown on coloured stickers  
located above the gas entry point and next 

to the rating plate.  Check that this is correct 
for the gas supply the appliance is being  
installed for.  The gas conversion procedure is 
detailed in the Service Manual. 

b.  Supply Pressure required for this appliance is 

shown in the “Specifications” section of this 
manual.  Check the gas supply to ensure that 
adequate supply pressure exists. 

WARNING: 

 
D

O

 

NOT

 

USE

 

A

 

NAKED

 

FLAME

 

TO

 

CHECK

 

FOR

 

GAS

 

LEAKAGES

 

Combustible 

Surface 

Non Combustible 

Surface 

LH / RH Side 

50mm 

0mm 

Rear 

50mm 

0mm 

Summary of Contents for CF2

Page 1: ...I N S T A L L A T I O N A N D O P E R A T I O N M A N U A L 236865 6 400mm Gas Fryer Model CF2 ...

Page 2: ...ONAL CONTACTS AUSTRALIA Moffat Pty Limited E Mail vsales moffat com au Main Office tel 61 03 9518 3888 fax 61 03 9518 3833 Service tel 1800 622 216 Spares tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co ...

Page 3: ...eration 8 Operation Guide 8 Description of Controls 8 Before Use 9 Filling the Tank 9 Lighting the Pilot Burner 9 Lighting the Main Burner 10 Set the Operating Temperature 10 Turning Fryer to Pilot or Off Positions 10 Guide and Care of Frying Oils and Fats 10 Part 5 Cleaning and Maintenance 11 General 11 Draining and Cleaning 11 Daily Cleaning 11 Weekly Cleaning 12 Periodic Maintenance 12 Part 6 G...

Page 4: ...INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOCATION THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER WARNING GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF FIRE THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERV...

Page 5: ...tions the appliance will be used in Recommended Gas Hose Assembly Specification AS NZS 1869 Class B or D compliant or equivalent that meets the following requirements Model Covered in this Specification CF2 400mm GAS FRYER Single Tank 18 Ltr General A commercial gas fired fryer fitted with a 90MJ hr Multi Jet Target U Burner and pilot burner controlled by a single gas controller which controls bot...

Page 6: ...Both the Knock Out Plug and External Regulator are supplied in the Town Gas Conversion Kit Refer to the Gas Conversion and Specifications section of this manual for further details Natural Gas G20 Propane G31 Heat Input nett 22 5 kW 22 5 kW Gas Rate 2 26 m3 hr 1 75 kg hr Supply Pressure 20 mbar 37 mbar Burner Operating Pressure 9 0 mbar 25 mbar Gas Connection 3 4 BSP Male Gas Natural LP Gas Butane...

Page 7: ...revent the occurrence of unacceptable concentrations of health harmful substances in the room the appliance is installed in Cobra gas fryers are designed to provide years of satisfactory service and correct installation is essential to achieve the best performance efficiency and trouble free operation This appliance must be installed in accordance with National installation codes and in addition i...

Page 8: ...the pilot needs adjusting this should be carried out by a qualified service agent Clearances NOTE Only non combustible materials can be used in close proximity to this appliance To facilitate easy operation drainage and servicing of the fryer a minimum of 600mm clearance should be maintained at the front of the appliance Any gas burning appliance requires adequate clearance and ventilation for opt...

Page 9: ...ons in this manual c Check the thermostat calibration once the oil is up to temperature If a discrepancy is found thermostat calibration should be referred to the supplier d Ensure that each operator has been instructed in the areas of correct lighting operation and shutdown procedures for the appliance Initial Start Up a For first time use of the new fryer prior to using for cooking product fill ...

Page 10: ...t impossible however bad operation practices can reduce the oil shortening life and produce a poor quality product To use this fryer correctly please read the following sections carefully Filling the Tank Lighting the Pilot Burner Lighting the Main Burner Setting the Operating Temperature Draining and Cleaning Single Tank CF2 Controls CAUTION This appliance is for professional use and is only to b...

Page 11: ...upply is turned On 2 Check that there are no foreign articles in the tank Filling the Tank NOTE Cobra fryers can be used with both oil and shortening 1 Before filling the tank always check that the drain valve behind the access door is closed A locking slide is provided on this valve and this should always be locked in position during use a OIL Carefully fill fryer tank with oil until the FILL LEV...

Page 12: ... a minute or two after they are taken from fryer Fried foods should never be held Lighting the Main Burner 1 Ensure pilot burner is alight by visually checking through the Pilot Burner Viewing Opening 2 Rotate Thermostat Control Knob to temperature required 3 Rotate Gas Control Knob to Main Burner position 4 Main burner will ignite automatically off the pilot burner NOTE If main burner is turned O...

Page 13: ...ults occur have them attended to promptly Don t wait until they cause a complete breakdown It is recommended that the appliance is serviced every 6 months Clean the fryer regularly A clean fryer looks better will last longer and will perform better NOTE DO NOT use abrasive detergents sharp scrapers strong solvents or caustic detergents as they could corrode or damage the fryer Ensure that any dete...

Page 14: ...se a small vessel with a handle as a ladle and dip into the hot frying medium from receptacle and pour vigorously around sides and bottom of the tank to wash out crumbs and particles adhering to them Continue to dip and pour until all crumbs are washed down and into the filter bag 7 Open drain valve fully check for any particles or crumb residue lodged in the valve Clean out with a stiff nylon bru...

Page 15: ...meets the following requirements 1 Ensure that the gas supply has been turned Off 2 Open the front door of the fryer to access the main burner and pilot burner in jectors 3 Disconnect 2 wires from the Thermostat to the Gas Control Valve 4 Disconnect 2 wires from the Overtemp at the electrical connector 5 Cut and remove any cable ties as required 6 Disconnect the flexi tube gas connection at the to...

Page 16: ... in Town Gas Kit and the operating pressure adjusted at the External Gas Pressure Regulator Both the Knock Out Plug and External Regulator are supplied in the Town Gas Conversion Kit 1 Remove slotted cap from regulator 2 Turn On gas supply and appliance 3 Adjust pressure adjusting screw to achieve correct burner operating pressure NOTE Measure operating pressure at the Gas Control Valve Out test p...

Page 17: ...W 1 turns out CCW Burner Operating Pressure 0 90 kPa 9 0 mbar 2 50 kPa 25 mbar Supply Pressure 20 mbar 37 mbar Natural Gas LP Gas Propane Main Burner Injectors Ø 1 55mm Ø 0 95mm Pilot Burner Injectors 0 62 0 35 Pilot Screw Adjustment Full Out CCW 1 turns out CCW Burner Operating Pressure 0 90 kPa 9 0 mbar 2 50 kPa 25 mbar Supply Pressure 1 13 2 0 kPa 2 75 3 0 kPa Natural Gas LP Gas Butane Main Bur...

Page 18: ...ostat MV Fryer 90 190ºC 236848 Knob 100 190ºC 018022K Overtemp Control Kit 018089K Gas Control Valve Kit General 236768 Basket Support Rack 236742 Basket Hangar 018019 Fryer Basket 227856 Door Magnet 227466 Door Catch Receiver 236795 Drain Valve 018147 Drain Extension 236769 Adjustable Leg 150mm 229674 Rear Roller Assy 236933 Fryer Lid Optional Extra 18176 Drain Stick Optional Extra Only Gas Conve...

Page 19: ......

Reviews: