Part 6  Gas Conversion 

Main Burner Injectors 

1.  To remove Main  

Burner Injectors, use a 
spanner to prevent 
Injector Insert from 
turning while  
removing injector. 

2.  Replace with the  

correct size injectors. 

3.  Refit burner assembly 

back into burner box. 

 

Pilot Burner Injectors 

1.  Unscrew pilot supply tube from pilot burner and 

remove pilot injector. 

2.  Determine correct sized pilot injectors for the  

corresponding gas from the table overleaf. 

3.  Fit correct sized injector into pilot burner and  

re-connect gas supply tube to the pilot burner. 

 

Supply Pressure Check 

1.  Remove the blanking screw and connect a  

manometer to the Supply Pressure Test Point 
(‘IN’) on Gas Control Valve. 

2.  Turn ‘On’ the gas supply and ensure that the  

pressure is within specifications shown in ‘Gas 
Specifications Table’ at rear of this section. 

 
 
 
 

 
 
 

 

 
 

 
 
 

 
 
 
 
 
 

Main Burner Operating Pressure Adjustment 

1.  Connect a manometer to Operating Pressure 

Test Point (‘OUT’) on the gas control valve. 

2.  Remove slotted cap to reveal Operating  

Pressure Adjusting Screw

3.  Light Main Burner and turn Operating Pressure 

Adjusting Screw to obtain correct burner  
pressure for type of gas being used.  Refer to 
Gas Specifications Table at rear of this section. 

4.  Remove manometer from Operating Pressure 

Test Point and refit blanking screw. 

5.  Refit slotted cap to screw adjustment point. 

Supply Pressure 

Test Point 

Operating 

Pressure 

 Test Point 

Operating 

Pressure 

Adjusting Screw 

Pilot Burner 

Adjusting 

Screw 

Injector Mounting Bush 

Injector 

Town Gas Only 
NOTE: 
For Town Gas application, Gas Control Valve -
Operating Pressure Adjusting Screw should be 

 

replaced with the Knock Out Plug supplied in Town 
Gas Kit and the operating pressure adjusted at the 
External Gas Pressure Regulator.  Both the Knock Out 
Plug and External Regulator are supplied in the Town 
Gas Conversion Kit. 

 

1. Remove slotted 

cap from regulator. 

2.  Turn ‘On’ gas 

supply and 
appliance. 

3.  Adjust pressure  

adjusting screw to 
achieve correct 
burner operating 
pressure. 

 

NOTE: 

Measure operating pressure at the Gas 

 

Control Valve ’Out’ test point with burner operating. 

 

4.  Verify operating pressure remains correct  

(Re-adjust regulator if required). 

5.  Screw cap nut back onto regulator. 

 

Pilot Burner Flame Adjustment 
1.  Once main burner operating pressure has been 

set, adjust pilot burner supply so that pilot flame 
impingement onto thermocouple and 
thermopile is correct and main burner pilot flame 
ignites main burner satisfactorily. 

2.  Adjust pilot flame size by adjusting Pilot Burner 

Adjusting Screw.  Pilot burner flame should be 
approximately 1" long for main burner ignition.  
Anti-clockwise rotation of adjustment screw will 
increase size of pilot flame. 

 

Gas Type Identification Label 
On completion of gas conversion, replace gas type 
identification label located at:- 

-  Rear of appliance, above gas connection. 
-  Beside the Rating Plate. 

 

Commissioning 
Before leaving the converted installation; 
1.  Check all gas connections for leakages using 

soapy water or other gas detecting equipment. 

 
 
 
2.  Check the following functions in accordance 

with the operating instructions specified in the 
‘Operation’ section of this manual. 



Light the Pilot Burner. 



Light the Main Burner. 



Check the Thermostat operation. 



Ensure that all the controls operate correctly. 

 

NOTE: If it is not possible to get the fryer to operate 
correctly, shut Off the gas supply and contact the 

supplier of this appliance. 

WARNING: 

 

D

O

 

NOT

 

USE

 

A

 

NAKED

 

FLAME

 

TO

 

CHECK

 

FOR

 

GAS

 

LEAKAGES

Pressure 

Adjusting 

Screw 

Cap Nut 

Summary of Contents for CF2

Page 1: ...I N S T A L L A T I O N A N D O P E R A T I O N M A N U A L 236865 6 400mm Gas Fryer Model CF2 ...

Page 2: ...ONAL CONTACTS AUSTRALIA Moffat Pty Limited E Mail vsales moffat com au Main Office tel 61 03 9518 3888 fax 61 03 9518 3833 Service tel 1800 622 216 Spares tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co ...

Page 3: ...eration 8 Operation Guide 8 Description of Controls 8 Before Use 9 Filling the Tank 9 Lighting the Pilot Burner 9 Lighting the Main Burner 10 Set the Operating Temperature 10 Turning Fryer to Pilot or Off Positions 10 Guide and Care of Frying Oils and Fats 10 Part 5 Cleaning and Maintenance 11 General 11 Draining and Cleaning 11 Daily Cleaning 11 Weekly Cleaning 12 Periodic Maintenance 12 Part 6 G...

Page 4: ...INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOCATION THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER WARNING GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF FIRE THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERV...

Page 5: ...tions the appliance will be used in Recommended Gas Hose Assembly Specification AS NZS 1869 Class B or D compliant or equivalent that meets the following requirements Model Covered in this Specification CF2 400mm GAS FRYER Single Tank 18 Ltr General A commercial gas fired fryer fitted with a 90MJ hr Multi Jet Target U Burner and pilot burner controlled by a single gas controller which controls bot...

Page 6: ...Both the Knock Out Plug and External Regulator are supplied in the Town Gas Conversion Kit Refer to the Gas Conversion and Specifications section of this manual for further details Natural Gas G20 Propane G31 Heat Input nett 22 5 kW 22 5 kW Gas Rate 2 26 m3 hr 1 75 kg hr Supply Pressure 20 mbar 37 mbar Burner Operating Pressure 9 0 mbar 25 mbar Gas Connection 3 4 BSP Male Gas Natural LP Gas Butane...

Page 7: ...revent the occurrence of unacceptable concentrations of health harmful substances in the room the appliance is installed in Cobra gas fryers are designed to provide years of satisfactory service and correct installation is essential to achieve the best performance efficiency and trouble free operation This appliance must be installed in accordance with National installation codes and in addition i...

Page 8: ...the pilot needs adjusting this should be carried out by a qualified service agent Clearances NOTE Only non combustible materials can be used in close proximity to this appliance To facilitate easy operation drainage and servicing of the fryer a minimum of 600mm clearance should be maintained at the front of the appliance Any gas burning appliance requires adequate clearance and ventilation for opt...

Page 9: ...ons in this manual c Check the thermostat calibration once the oil is up to temperature If a discrepancy is found thermostat calibration should be referred to the supplier d Ensure that each operator has been instructed in the areas of correct lighting operation and shutdown procedures for the appliance Initial Start Up a For first time use of the new fryer prior to using for cooking product fill ...

Page 10: ...t impossible however bad operation practices can reduce the oil shortening life and produce a poor quality product To use this fryer correctly please read the following sections carefully Filling the Tank Lighting the Pilot Burner Lighting the Main Burner Setting the Operating Temperature Draining and Cleaning Single Tank CF2 Controls CAUTION This appliance is for professional use and is only to b...

Page 11: ...upply is turned On 2 Check that there are no foreign articles in the tank Filling the Tank NOTE Cobra fryers can be used with both oil and shortening 1 Before filling the tank always check that the drain valve behind the access door is closed A locking slide is provided on this valve and this should always be locked in position during use a OIL Carefully fill fryer tank with oil until the FILL LEV...

Page 12: ... a minute or two after they are taken from fryer Fried foods should never be held Lighting the Main Burner 1 Ensure pilot burner is alight by visually checking through the Pilot Burner Viewing Opening 2 Rotate Thermostat Control Knob to temperature required 3 Rotate Gas Control Knob to Main Burner position 4 Main burner will ignite automatically off the pilot burner NOTE If main burner is turned O...

Page 13: ...ults occur have them attended to promptly Don t wait until they cause a complete breakdown It is recommended that the appliance is serviced every 6 months Clean the fryer regularly A clean fryer looks better will last longer and will perform better NOTE DO NOT use abrasive detergents sharp scrapers strong solvents or caustic detergents as they could corrode or damage the fryer Ensure that any dete...

Page 14: ...se a small vessel with a handle as a ladle and dip into the hot frying medium from receptacle and pour vigorously around sides and bottom of the tank to wash out crumbs and particles adhering to them Continue to dip and pour until all crumbs are washed down and into the filter bag 7 Open drain valve fully check for any particles or crumb residue lodged in the valve Clean out with a stiff nylon bru...

Page 15: ...meets the following requirements 1 Ensure that the gas supply has been turned Off 2 Open the front door of the fryer to access the main burner and pilot burner in jectors 3 Disconnect 2 wires from the Thermostat to the Gas Control Valve 4 Disconnect 2 wires from the Overtemp at the electrical connector 5 Cut and remove any cable ties as required 6 Disconnect the flexi tube gas connection at the to...

Page 16: ... in Town Gas Kit and the operating pressure adjusted at the External Gas Pressure Regulator Both the Knock Out Plug and External Regulator are supplied in the Town Gas Conversion Kit 1 Remove slotted cap from regulator 2 Turn On gas supply and appliance 3 Adjust pressure adjusting screw to achieve correct burner operating pressure NOTE Measure operating pressure at the Gas Control Valve Out test p...

Page 17: ...W 1 turns out CCW Burner Operating Pressure 0 90 kPa 9 0 mbar 2 50 kPa 25 mbar Supply Pressure 20 mbar 37 mbar Natural Gas LP Gas Propane Main Burner Injectors Ø 1 55mm Ø 0 95mm Pilot Burner Injectors 0 62 0 35 Pilot Screw Adjustment Full Out CCW 1 turns out CCW Burner Operating Pressure 0 90 kPa 9 0 mbar 2 50 kPa 25 mbar Supply Pressure 1 13 2 0 kPa 2 75 3 0 kPa Natural Gas LP Gas Butane Main Bur...

Page 18: ...ostat MV Fryer 90 190ºC 236848 Knob 100 190ºC 018022K Overtemp Control Kit 018089K Gas Control Valve Kit General 236768 Basket Support Rack 236742 Basket Hangar 018019 Fryer Basket 227856 Door Magnet 227466 Door Catch Receiver 236795 Drain Valve 018147 Drain Extension 236769 Adjustable Leg 150mm 229674 Rear Roller Assy 236933 Fryer Lid Optional Extra 18176 Drain Stick Optional Extra Only Gas Conve...

Page 19: ......

Reviews: