Sea Tel 2400 Dual Band C/Ku
2400 Dual Band Technical Specifications
18-7
EAR Controlled - ECCN EAR99
ADE Environmental Conditions
Temperature Range (Operating)
-25º to +55º Celsius (-13º to +131º F)
Humidity
100% Condensing
Wind Speed
56 m/sec (125 mph)
Solar Radiation
1,120 Watts per square meter, 55º Celsius
Spray
Resistant to water penetration sprayed from any
direction.
Icing
Survive ice loads of 4.5 pounds per square foot.
Degraded RF performance will occur under icing
conditions.
Rain
Up to 101.6mm (4 inches) per hour. Degraded RF
performance may occur when the radome surface is wet.
Corrosion
Parts are corrosion resistant or are treated to endure
effects of salt air and salt spray. The equipment is
specifically designed and manufactured for marine use.
Chemically Active Substances
Environmental Condition
Test Level
Sea Salt
5 percent solution
18.1.
Below Decks Equipment
Media Xchange Point (MXP)
Standard 19 Inch Rack mount
One Unit High
Physical Dimensions
17 X 17 X 1.75 (Inches)/ 43.18 x 43.18 x 4.45 (cm)
Input Voltage
85-264 VAC, 47-63Hz, single phase, 110 Watts
Weight
6.6lbs/ 3.0 kgs
Front Panel
4 Modem LEDs (On the MXP Board)
2 MXP status LEDs