The following table shows the specifications of the SAILOR 6080.
Specifications
Value
Output power at
100 VAC - 240 VAC
300 W continuous
370 W peak (max. 2 min. with 10% duty cycle)
a
a. Output power capability depends on the mounting position (horizontal
or vertical), input voltage, ambient temperature and ventilation at the
place of installation.
Output power at
90 VAC - 100 VAC
270 W continuous
333 W peak (max. 2 min. with 10% duty cycle)
a
DC output (nominal)
31.2 VDC at 0 A
29.3 VDC at 10 A
28.7 VDC at 13 A
AC input voltage
115-230 VAC nominal, 100-240 VAC operating
Alarm in case of
AC power failure
IP rating
IP 30
Operating temperature
-15° to +55° C
Storage temperature
-40° to +80° C
Cooling
The SAILOR 6080 must be placed in a
ventilated area with free space around all sides
of the unit, except the bottom side.
Heat dissipation
31,104 Kcal / hour
Survival temperature
(power on)
-40° to +80° C