Chapter 2: Installation
14
Installing the SAILOR 6080 Power Supply
2.2.6.5 AC alarm output
The AC alarm output provides an alarm signal when the SAILOR 6080
Power Supply cannot deliver the required power from the AC input. This is
the case when
• No AC power is present.
• The AC fuse is blown.
• The on/off switch is in the position off.
• The output is short-circuited or heavily overloaded.
• An internal error has occurred.
To wire the
AC alarm
output do as follows:
1. Attach the cable to the connector marked
AC Alarm
according to the
specifications in the table below:
AC ALARM (SAILOR 6080 Power Supply)
Connector type
Spring loaded terminal
Wire cross section
Up to 1.5 mm
2
Terminal 1
Closed when ok
Terminal 2
Open when ok
Terminal 3
Common
Terminal 4
GND