background image

 

Page 3 of 10 

 

www.cobham.com/satcom

Spare Part Instruction – SAILOR 100, 800 & 900A/B PMM 
Document No.: 97-138940-D 
Revision: D 

Log into the Antenna Control Unit (ACU): 

1.

 

Connect a straight through Ethernet cable from the LAN port of your laptop to the “LAN 3” port 
of the ACU. 

 

 

2.

 

Open the “Network and Sharing Center” on your laptop and select “Change Adaptor Settings”.   

 

 

3.

 

Right-Click the LAN adaptor for your laptop and select the “Properties” tab.  

 

 

Continued… 

 

 

 

Summary of Contents for SAILOR 100 TV

Page 1: ...smit signal is correctly aligned to prevent interference with the services on the opposite polarity The PMM drives a stepper motor on the back of the dish to rotate the polarization unit of the VSAT a...

Page 2: ...ice LED would also be illuminated red All power LED s should remain green providing they are receiving voltage Troubleshooting Diagnostic LEDs on the ACU The ACU has 3 LEDs Power Logon and Fail Pass V...

Page 3: ...Log into the Antenna Control Unit ACU 1 Connect a straight through Ethernet cable from the LAN port of your laptop to the LAN 3 port of the ACU 2 Open the Network and Sharing Center on your laptop an...

Page 4: ...TCP IPv4 Option 5 The Select the Use the following IP address button and enter in an IP address of 192 168 0 2 and a Subnet Mask of 255 255 255 0 6 Now click the OK button on both the IP Protocol Vers...

Page 5: ...Instruction SAILOR 100 800 900A B PMM Document No 97 138940 D Revision D 8 You ll now have access to the systems DASHBOARD 9 The following procedure will tell you how to access the events list and di...

Page 6: ...t page then shows a list of active events and notifications including The time and date of the first occurrence Time UTC The event code ID The severity of the event message Severity A description desc...

Page 7: ...to the antenna using the service switch located on the rear of the pedestal 4 Locate the PMM on the rear of the dish 5 Rotate the antenna dish to 90 degrees of elevation facing upwards 6 Press in and...

Page 8: ...connector with the coloured wires polarization encoder to the plug marked ORE on the PMM 13 Connect the 6 pin connector with 4 white wires to the plug marked ZRM on the PMM 14 Connect the 6 pin connec...

Page 9: ...d stop to end stop and then back to its zero reference point at which point the polarization motor module will be at the highest point with the LNB coax cables pointing left The TV antenna wont drive...

Page 10: ...oting Self Test You can run a self test on the ACU and ADU of the antenna system 1 From the HELPDESK page click the Self test option 2 The system will now run the Self test 3 Ensure the test is comple...