Page 8 of 10
www.cobham.com/satcom
Spare Part Instruction – SAILOR 100, 800 & 900A/B PMM
Document No.: 97-138940-D
Revision: D
11. To install a replacement PMM follow the instructions
above in reverse order, while following the below
guidelines:
12. Connect the 6-pin connector with the coloured wires
(polarization encoder) to the plug marked “ORE” on the
PMM.
13. Connect the 6-pin connector with 4 white wires to
the plug marked “ZRM” on the PMM.
14. Connect the 6-pin connector with 6 white wires to
the plug marked “OMT” on the PMM.
*Note: These wires don’t apply to the SAILOR 100 TV
antenna.
15. Once the replacement PMM has been installed verify
that the antenna passes the Power On Start up Test
(POST) as per the following procedure.