2
Set the IP Address
method as either
Dynamic or Static.
3.
Set the DNS or Gateway
address.
6.7. Integration into the AEM
When the repeater has been installed at site and the remote communication has been enabled, the
repeater can be integrated to the Active Element Manager. This is done by the operator of the AEM.
After entering the telephone number to the repeater, the AEM dials up the repeater, downloads all
the repeater parameters and statuses into a database. When all parameters have been downloaded,
the AEM configures the repeater with the telephone number where alarms and reports should be
sent, and optionally with a secondary telephone number where the repeater can dial in case
connection to primary number fails.
When heartbeat reports and alarms are sent from the repeater to the AEM also the latest information
about the status and RF-configuration is included. This means that the AEM operator always has
information about the current status in the AEM database (and do not need to call the repeater to
find this out).
Note!
Once the repeater is integrated to the AEM, all changes to the repeater should preferably be
done from the Active Element Manager in order to ensure that the database always contains
correct information.