1
Technical Specifications
1-16
BBG-1022-FS PRODUCT MANUAL
BBG1022FS-OM (V1.4)
The user interface is based on common SCTE 104 operations: Splice Start
Normal, Splice Start Intermediate, Splice End Normal, Splice End
Intermediate, and Splice Cancel (splice_request_data variants), offering full
control of splice start, end, and cancel as well as pre-roll and break duration
offsets. (A Manual Supplement is planned for this option. Please check
product web page.)
Alarm Function
The card can be set to monitor input video/audio for input errors such as input
LOS, frozen or black frame, loss of reference, closed captioning ancillary data
loss, and/or per-channel audio absences. These alarms can be propagated as a
card general error or warning message, and can be downloaded as basic .txt
logs or via a Syslog function.
User setup tables configure the alarm severity escalation as well as trigger
holdoff/release and other thresholds as applicable.
User Control Interface
BBG-1022-FS uses an HTML5 internal web server for control/monitoring
communication, which allows control via a web interface with no special or
unique application on the client device. Connection to the device to the
network media connection is via a standard 10/100/1000 RJ-45 Ethernet
connection. The device can also be controlled using DashBoard™ remote
control, where it appears as a frame connection.
Technical Specifications
Table 1-1 lists the technical specifications for the BBG-1022-FS 3G/HD/
SD-SDI Standalone Frame Sync with Audio/Video Processing, AES/Analog
Audio Embedding/De-Embedding, CVBS I/O, and Dual-Channel Option
(+2FS) unit.