9902-2UDXDI-OM (V1.0)
9902-2UDX-DI PRODUCT MANUAL
3-17
Operating Instructions
9902-2UDX-DI Function Menu List and Descriptions
(continued)
• Initial Startup Format Select
Selects a frame sync format/rate to be invoked (from the choices shown
to the left) in the time preceding stable lock to external reference.
Set this control to that of the intended external reference to help ensure
smoothest frame sync locking. This control also sets the card test pattern
format where the card initial output at power-up is the internal pattern
instead of program video.
• Program Video Output Mode Select
Provides a convenient location to select between card program video
output and other technical outputs from the choices shown to the left and
described below.
• Input Video – card outputs input program video (or loss of signal
choices described below).
• Flat Field (Black) – card outputs black flat field.
• Freeze – card outputs last frame having valid SAV and EAV codes.
• Test Pattern – card outputs standard technical test pattern (pattern
is selected using the Pattern drop-down described below).
• Snow – card outputs snow multi-color pattern.
• Loss of Input Signal Selection
In the event of program input video Loss of Signal (LOS), determines
action to be taken as follows:
• Disable Outputs: Disable program video SDI outputs.
• Flat Field – go to flat field on program video output.
• Freeze – go to last frame having valid SAV and EAV codes on
program video output.
• Test Pattern – go to standard technical test pattern on program
video output (pattern is selected using the Pattern drop-down
described below).
• Snow – output snow multi-color pattern.
• Test Pattern Select
Provides a choice of standard technical patterns (shown to the left) when
Test Pattern is invoked (either by LOS failover or directly by selecting
Test Pattern on the Program Video Output Mode Select control).
Table 3-2
9902-2UDX-DI Function Menu List — continued
Summary of Contents for 9902-2UDX-DI
Page 107: ......