DRAINING AND WINTERIZING

DRAINING YOUR SPA 

After  a  period  of  3-4  months,  detergent  residues  from  bathing 
suits  and  soap  film  will  build  up  in  your  spa  water.  Once 
this happens, your spa water will appear cloudy and should 
probably be replaced. 

Turn power OFF at the breaker.

Locate the drain valve (usually in the equipment area).

Remove the safety cap and attach garden hose.

Drain water to a convenient area (Spa water may harm grass
or plants if sanitizer levels are high.)

When water begins to flow out of the hose, open the air relief
valve  located  on  filter  lid  (Hydro-Cyclonic  Filtration)  or  Air
Bleeder Valve (Skim Filtration).

Your spa will drain except for a small portion left in the foot
well. This can be removed with a sponge and pail.

Once empty, clean as required.

To finish, remove garden hose and attach safety cap.

IMPORTANT  (Cascade  Series  Only): 

There  will  be  an 

additional  drain  valve.  This  is  connected  directly  to  the  tank 
reservoir and you will see the water level go down on the sight 
tube in the equipment area. 

WINTERIZING YOUR  SPA 

In many areas of the world the temperature may drop below 32°
F (0°C). We recommend the spa is always filled with water and 
running  at  normal  spa  temperatures.  By  doing  this  you  will 
minimize the risk of freezing within your spa. If it is necessary to 
leave your spa unattended for long periods of time during cold 
weather  conditions,  you  should  drain  your  spa  to  avoid 
accidental freezing caused by power outages. 
Your  local  dealer  can  perform  the  following  winterizing 
procedures, if you are not completely comfortable with them. 

 

Ensure  that  you  have  fully  drained  the  spa  (Refer  to  the
DRAINING YOUR  SPA section).

 

After draining, your spa may still have water remaining in the
equipment  and  plumbing  fittings.  Disconnect  the  hand-
tightened union fittings going to and from the jet pumps. Be

careful not to lose the O-rings between the unions and pump 
housing. 

Leave drain valve in the open position and safety cap off .

To  completely  drain  the  plumbing  lines,  a  wet/dry  shop
vacuum can be used to draw out any remaining water. Place
the vacuum hose over the jet fittings in the spa as well as the
plumbing  lines  in  the  equipment  area.  You  should  also
disconnect  the  plug  on  the  crystal  clear  inspection  tube  (if
installed).

Remove the filter cartridge and store in a warm, dry area.

Clean the spa shell and place spa cover on spa. Be sure to
lock the cover in place in case of high winds or rain.

WARNIN

G

The  instructions  above  should  be  followed 

accordingly  when  winterizing  your  spa  however  they  are 
guidelines  and  potential  freeze  damage  may  still  occur.  All 
freeze damage is the sole responsibility of the spa owner and 
will not be covered by the warranty should it occur. 

EMER

G

EN

C

Y  SITUATIONS: 

To  eliminate  freezing  in  the 

event  of  equipment  failure,  use  a  100-watt  light  bulb  or  small 
heater  via  extension  cord  and  place  it  in  the  equipment  area, 
keeping it away from plumbing lines. This will help for a short 
period of time until proper service can be rendered. 

Summary of Contents for Purfikt Spa

Page 1: ...Coast Spas Manufacturing 6315 202 Street Langley BC Canada V2Y 1N1 info coastspas com www coastspas com 2021 Owner s Manual Purfikt Spa ...

Page 2: ...OWNER S MANUAL PURFIKT SPA 2021 2 ...

Page 3: ...a selling dealer if you have any queries related to your Purfikt spa Coast Spas authorized dealers are trained professionals who can assist you with spa parts setup operations maintenance and technical support CONGRATULATIONS YOU RE ALMOST READY TO ENJOY YOUR NEW SPA Before you begin to enjoy your spa please take a moment to submit your spa warranty For registering your spa you will need the spa s...

Page 4: ...ed by the supplier of the true variable speed pumps the Siemens brand GFCI can filter electrical spikes and avoid false trips The use of a 60 Amp Siemens GFCI is recommended with the Atlas System Glossary of terms Preparation set up and location of your new spa Spa general layout Spa features and specifications Start Up Guide Infinity Edge Spas Spa Care Guide Basic installation and configuration g...

Page 5: ...ill require either a 40 50 or 60 Amp dedicated circuit breaker with the proper wire size gauge based on the length of the run The electrical circuit must be installed by a certified electrician and approved by a local building or electrical inspector Surface Transport Your new spa has left the factory cleaned and polished and ready to begin operation after passing our many quality and operational ...

Page 6: ...rs not smaller than No 6 AWG when spa use exceeds 10 minutes Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibly pregnant women should limit spa water temperatures to 100 F 38 C If pregnant please consult your physician before using a spa Before entering the spa the user should measure the water temperature wit...

Page 7: ...ll help to discourage unsupervised children from entering the spa and keep the spa cover secure in high wind conditions There is no representation that the cover clip tie downs or actual locks will prevent access to the spa CAUTION For exercise the water should not exceed 90 F 32 C GLOSSARY OF TERMS AIR CONTROL Mounted generally on the lip of the spa it induces warm air from the equipment enclosur...

Page 8: ...able high intensity hydrotherapy jet VOLCANO JET high output jet designed for foot and leg massage FUSION JETS Coast Spas Fusion Jets provide a seamless and smooth surface to relax against while you enjoy a therapeutic massage from various jet types all positioned to maximize hydrotherapy Digital Float and Fill Gauge The illuminated fill gauge for all Cascade Series Spas takes the guesswork out of...

Page 9: ...agram below Spacing the straps may require slight adjustments to ensure the load is balanced The chains attached to the crane must be a minimum of 18 feet in length from the point of lifting Using chains smaller than 18 feet will add stress to the outer lip of the spa and may result in damage Using the appropriately weighted straps and chains is important to ensure the safe handling of the PURFIKT...

Page 10: ...1 Volcano Jet 12 Ozone Cluster 13 5 Spa Light 14 Skimmers 15 Spa LED 16 Air Relief DISCLAIMER At the time of print this manual is accurate in its information Coast Spas reserves all the rights to change modify any swim spa designs and or features without notification To check on updates or for other information please visit www coastspas com DISCLAIMER The pictures displayed above are for referenc...

Page 11: ...em but it also removes the dirty filter canisters from the bathing area Patented Technology and Design Always Perfect In a Coast Spas Cascade Series Spa the water level will always stay the same regardless of how many people are in the Spa Largest Skimmers Coast spas is proud to offer the largest skimmer in the industry this allows our Spas to remove debris from the surface of the Spa and help to ...

Page 12: ...for 60 seconds Continue running pumps 2 3 pump 2 on 2 pump models turn pump 1 on high speed for 20 seconds by pressing the pump 1 icon twice Continue running pumps 2 3 pump 2 on 2 pump models on high speed for 30 seconds and activate pump 1 on high speed for 20 seconds Cascade check valve inside the equipment area full of water is an indication of no more air in the plumbing line If the check valv...

Page 13: ...balanced spa water If you suspect that your chemicals may be unbalanced remove your pillows immediately until the water has been restored to suggested conditions Do not sit on the pillows Do not pull on the pillows Pillows should be cleaned using a soft cloth and mild soap then wiped with a conditioner We recommend that pillows be washed each time you drain you spa This Limited Warranty is void if...

Page 14: ...l cared for spa cover is a thing of beauty in its own right Be sure to clean and condition your cover at least once a month more often if needed WEATHERSHEILD COVER MAINTAINANCE PROCEDURE Weather shield is a solution dyed polyester fabric designed to be flexible and easy for manufacturers to use Its urethane coating enhances the stability of the weave and allows for greater water resistance while ...

Page 15: ...mum 6AWG copper conductors only Torque field connections between 21 and 23 lbs Readily accessible disconnecting means to be provided at time of installation Permanently connected power supply Connect only to a circuit protected by a Class A Ground Fault Circuit Interrupter GFCI or Residual Current Device RCD mounted at least 5 1 52M from the inside walls of the spa and in line of sight from the eq...

Page 16: ...horized dealer to purchase suitable lubricant Place clean Cartridge in filter canister Replace filter lid and re tighten retaining ring finger tight only Note Make sure the O ring is on the air relief valve and is finger tight prior to starting the pump This O ring should periodically be lubricated with a silicone lubricant There is a 3 8 clear line coming from the filter area and this goes to the...

Page 17: ...maintenance you can do for yourself Total Alkalinity This refers to the ability of the spa water to resist changes in pH Controlling alkalinity can help keep your pH in the appropriate range thereby lessening the need for pH balancing If the TA is too low the pH level will fluctuate rapidly from high to low If the TA is too high the pH will tend to be too high and will be very difficult to bring b...

Page 18: ...too low High metal content in water Adjust alkalinity Adjust pH Use stain and scale product Poor filtration pH is too high Hardness is too high Total alkalinity is too high Suspended particles Clean filter cartridge Adjust pH Adjust hardness Adjust total alkalinity Drain and refill spa water pH is too high Sanitizer is too low Adjust pH Shock spa with sanitizer Adjust sanitizer level pH is too low...

Page 19: ...ing constantly will not turn off Filter cycle set to 24 hours Problem with the circuit board Turn off 24 hour filtration Turn power off at GFCI and contact your Dealer Pump will not turn on GFCI tripped Motor has overheated Not plugged in Damaged plug Seized motor Blown fuse Motor vent is blocked Reset the GFCI Let cool for 1 hour Plug in to the board Contact your Dealer Contact your Dealer Check ...

Page 20: ...of time in cold weather cold wind Spa is wired for 110V and jets are on Put cover back onto spa and allow for heat to regenerate Call your dealer if temperature does not increase Spa wired for 110V only have enough power to heat or operate pumps Turn off jets to power heater PUMPS WILL NOT PRIME PROBABLE CAUSE RECOMMENDED ACTION Pump on but no water flow Air trapped in pump No water in the pump Cl...

Page 21: ...ould drain your spa to avoid accidental freezing caused by power outages Your local dealer can perform the following winterizing procedures if you are not completely comfortable with them Ensure that you have fully drained the spa Refer to the DRAINING YOUR SPA section After draining your spa may still have water remaining in the equipment and plumbing fittings Disconnect the hand tightened union ...

Page 22: ...formation Coast Spas reserves all the rights to change modify any spa designs and or features without notification To check on updates or for other information please visit www coastspas com Waterfall Shutoff General Note ON OFF BLUE PURFIKT JET Note Cluster Jet Poly Jet Storm Jet Volcano Jet Ø PT V T ...

Page 23: ... will automatically go into sleep mode which turns the display off This is normal operation Touch anywhere on the screen to wake the panel up PURFIKT SPA CONTROL PANEL The Main Screen Lights Time Filter Cycle 1 Running Wi Fi Signal Indicator Lock Invert Screen High Temperature Range Heat Settings Temperature Scale F C Jets Set Temperature Clean up Cycle Ozone Running R Ready Mode RR Ready Rest Mod...

Page 24: ...oing on Exiting the System information Screen will take you back to the Message Screen in that situation OWNER S MANUAL PURFIKT SPA 2021 24 Adjust set temperature lower on inactive fatal error Spa can t function until it s fixed Normal Error or Warning Reminder Message Information Message disabled Message waiting indicator The Message Waiting Indicator will show ne of the following icons Adjust se...

Page 25: ...ment Below are some examples of 2 speed Pump indicators If the Spa has a Circ Pump a Circ Pump Icon will appear to indicate its activity but outside of Priming Mode the Circ Pump cannot be controlled directly One exception The Main Spa Light is not shown on the Spa Screen it is only shown and controlled on the Main Screen Jets Off Jets Low Jets High Common Buttons If an Up or Down button is shown ...

Page 26: ...etting Each range maintains its own set temperature as programmed by the user This way when a range is chosen the spa will heat to the set temperature associated with that range High Range can be set between 80 F and 104 F Low Range can be set between 50 F and 99 F More specific Temp Ranges may be determined by the Manufacturer Freeze Protection is active in either range Heat Mode Ready vs Rest Ci...

Page 27: ...on as the Priming Mode screeen appears on the panel select the Jets 1 button once to start Pump 1 in low speed and then again to switch to high speed Also select the other pumps to turn them on The pumps should be running in high speed to facilitate priming If the pumps have not primed after 2 minutes and water is not flowing from the jets in the spa do not allow the pumps to continue to run Turn ...

Page 28: ...ystems the ozone will generally run with the circ pump but can be limited to filtration cycles On some circs systems Pump 1 low will run along with the circ Pump during filtration The system is factory programmed with one filter cycle that will run in the evening assuming the time of day is prop erly set when energy rates are often lower The filter time and duration are programmable A second filte...

Page 29: ...l initiate a purge when Filter Cycle 2 is programmed to begin The Meaning of Filter Cycles 1 The heating pump always runs during the filter cycle 2 In Rest Mode heating only occurs during the filter cycle 3 Purges happen at the start of each filter cycle For example if your spa is set up for 24 hour circulation except for shutting off when the water temperature is 3 F 1 3 C above the set temperatu...

Page 30: ...de Drain Mode Some spas have a special feature that allows Pump 1 to be employed when draining the water When available this feature is a component of Hold Mode M0XX is a Message Code Codes like this will be seen in the Fault Log Utilities The Utilities Icon on the Settings Screen takes you to the Utilities Screen The Utilities Screen contains the following Panel Touching the Panel Icon on the Uti...

Page 31: ... can be used to reset the automatic test feature Units Screen The Units Icon on the Settings Screen takes you to the Units Screen Reminders The Reminder Icon on the Settings Screen takes you to the Reminders screen 1 Press Temp Display to change the temperature between Fahrenheit and Celsius 2 Press Time Display to change the clock between 12 hr and 24 hr display Press Reminders to turn the remind...

Page 32: ...CI must be reset once it has tripped After passing the GFCI Trip Test any subsequent GFCI trips will indicate a ground fault or other unsafe condition and the power to the spa must be shut off until a service person can correct the problem Touching the GFCI Test Icon on the Utilities Screen takes you to the GFCI Test screen CE Product CE registered systems do not have an RCD Test Feature due to th...

Page 33: ... and the spa is shut down You must reset the message when water is below 108 f 42 2 C See Flow Related Checks below Error Message Code 30 The heater is too hot Flow related checks Check for low water level suction flow restrictions closed valves trapped air too many closed jets and pump prime On some systems even when spa is shut down by an error condition some equipment may occasionally turn on t...

Page 34: ...The GFCI or RCD is an important safety device and must be tested on a regular basis to verify its reliability Every user should be trained to safely test the GFCI or RCD associated with the hot tub installation A GFCI or RCD will have a TEST and RESET button on it that allows a user to verify proper function Change the water May appear on a regular schedule i e every 90 days Change the water in th...

Page 35: ... Spa can be controlled by using the Balboa Worldwide App bwaTM that allows you to access your spa via a direct connection anywhere in the local proximity of your tub anywhere in your house that you can connect to your local Wi Fi network or anywhere in the World you have an Internet connection to your smart device via 3G 4G or Wi Fi The bwaTM app can be downloaded from Google play store or Apple A...

Page 36: ..._________________ _____________________________________________________________ ____________________ _____________________________________________________________ ____________________ _____________________________________________________________ ____________________ _____________________________________________________________ ____________________ __________________________________________________...

Page 37: ...______________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ ___________________________________________...

Page 38: ...38 WORLD S BEST BUILT SPAS ...