background image

1

 

 

OPERATION

 

MANUAL

 

Desktop

 

CO2,

 

Temperature

 

&

 

Relative

 

Humidity

 

Monitor

 

 

 

 

 

CO2METER.COM

   

 

INTRODUCTION

 

Thank

 

you

 

for

 

purchasing

 

this

 

desktop

 

CO2

 

monitor.

 

It

 

measures

 

carbon

 

dioxide

 

levels,

 

air

 

temperature

 

and

 

humidity.

 

This

 

makes

 

it

 

ideal

 

for

 

indoor

 

air

 

quality

 

(IAQ)

 

diagnosis

 

and

 

HVAC

 

system

 

performance

 

verification.

 

 

Poor

 

indoor

 

air

 

quality

 

is

 

considered

 

unhealthy.

 

It

 

can

 

lead

 

to

 

drowsiness,

 

inability

 

to

 

concentrate,

 

and

 

even

 

illness

 

(for

 

example,

 

Sick

 

Building

 

Syndrome).

 

 

IAQ

 

monitoring

 

of

 

CO2

 

levels

 

is

 

widely

 

used

 

in

 

public

 

areas

 

such

 

as

 

offices,

 

classrooms,

 

factories,

 

hospitals

 

and

 

hotels.

 

It

 

is

 

also

 

recommended

 

for

 

industrial

 

hygiene

 

in

 

some

 

countries.

 

(See

 

appendix).

 

 

Product

 

Features:

 

● 

Large

 

display

 

shows

 

CO2

 

level,

 

temperature,

 

   

humidity,

 

date

 

and

 

time

 

● 

15

 

degree

 

tilt

 

angle

 

makes

 

the

 

display

 

easy

 

   

to

 

see

 

and

 

read

 

● 

Indoor

 

air

 

quality

 

level

 

indication:

 

   

Good,

 

Normal,

 

and

 

Poor

 

● 

Stable

 

NDIR

 

sensor

 

for

 

CO2

 

detection

 

● 

Visible

 

and

 

audible

 

CO2

 

warning

 

alarm

 

● 

ABC

 

(Automatic

 

Baseline

 

Calibration)

 

   

or

 

manual

 

CO2

 

calibration

 

● 

Maximum

 

or

 

minimum

 

CO2

 

level

 

recall

 

   

function

 

 

MATERIALS

 

SUPPLIED

 

This

 

package

 

contains:

 

● 

Meter

 

● 

Power

 

Supply

 

(5V

 

+/

‐ 

10%,

 

>=

 

0.5A)

 

● 

Manual

 

 

POWER

 

SUPPLY

 

The

 

meter

 

is

 

powered

 

by

 

an

 

AC

 

adaptor

 

(5V/0.5A

 

output).

 

LCD

 

DISPLAY

 

 
 
 
 
 
 
 

Symbols

 

ppm

                 

CO2

 

level

 

in

 

parts

per

million

 

GOOD

               

CO2

 

is

 

in

 

good

 

level

 

NORMAL

           

CO2

 

is

 

in

 

normal

 

level

 

POOR

               

CO2

 

is

 

in

 

poor

 

level

 

Air

 

Temp.

         

Air

 

temperature

 

Humidity

 

%

       

Unit

 

of

 

air

 

relative

 

humidity

 

o

E

 

(C/F)

             

Celsius/Fahrenheit

 

of

 

temp.

 

MAX/MIN

         

Maximum/Minimum

 

readings

 

                         

CO2

 

alarm

 

icon

 

 

NOTE:

   

TWA

 

/

 

STEL

 

/

 

VENT.R

 

/

 

cfm/p

 

/

 

lps%

 

icons

 

are

 

not

 

used

 

for

 

this

 

model.

 

 

 

KEYPAD

 

SET

 

Enter

 

setup

 

mode

 

Save

 

and

 

finish

 

settings

 

ESC

Exit

 

setup

 

page

 

/

 

mode

 

      ‐

Terminate

 

CO2

 

calibration

 

RESET

 

‐ 

Clear

 

MAX/MIN

 

values

 

Select

 

mode

 

or

 

increase

 

value

 

in

 

setup

 

MIN/MAX

▼ 

Activate

 

MAX,

 

MIN

 

function

 

Select

 

mode

 

or

 

decrease

 

value

 

during

 

setup

 

SET

+

+

MIN/MAX

▼ 

‐ 

CO2

 

calibration

 

mode

 

 

OPERATION

 

POWER

 

ON/OFF

 

Plug

 

the

 

wall

 

adaptor

 

into

 

an

 

appropriate

 

receptacle.

 

The

 

meter

 

will

 

turn

 

on

 

automatically

 

after

 

a

 

short

 

beep.

 

The

 

lit

 

LED

 

indicates

 

full

 

power.

 

If

 

the

 

voltage

 

is

 

too

 

high

 

or

 

low,

 

“bAt”

 

will

 

display

 

on

 

the

 

LCD

 

and

 

the

 

LED

 

will

 

flash.

 

Please

 

see

 

page

 

14

 

for

 

trouble

 

shooting.

 

 

During

 

normal

 

operation,

 

the

 

LCD

 

will

 

display

 

the

 

current

 

CO2

 

level

 

in

 

ppm,

 

air

 

quality

 

level,

 

air

 

temperature,

 

humidity,

 

and

 

the

 

current

 

date

 

and

 

time

 

(Fig.1).

 

 

 

 

 

 

 

 

 

TAKING

 

MEASUREMENTS

 

The

 

meter

 

starts

 

taking

 

measurements

 

immediately

 

after

 

it

 

is

 

turned

 

on

 

and

 

updates

 

the

 

readings

 

every

 

second.

 

In

 

the

 

event

 

the

 

operating

 

environment

 

is

 

quickly

 

changed

 

(for

 

example,

 

from

 

high

 

to

 

low

 

temperature),

 

it

 

will

 

take

 

approximately

 

2

 

minutes

 

for

 

the

 

CO2

 

and

 

temperature

 

to

 

adjust

 

and

 

10

 

minutes

 

for

 

humidity

 

to

 

stabilize.

 

NOTE:

 

Do

 

not

 

hold

 

the

 

meter

 

close

 

to

 

your

 

face

 

as

 

your

 

breath

 

will

 

affect

 

the

 

CO2

 

level.

 

 

MIN/MAX

 

While

 

the

 

meter

 

is

 

powered

 

on,

 

press

 

the

 

MIN/MAX

 

button

 

to

 

see

 

the

 

minimum

 

and

 

maximum

 

CO2

 

level,

 

temperature,

 

and

 

humidity

 

in

 

turn.

 

Each

 

press

 

of

 

MIN/MAX

 

will

 

display

 

the

 

MIN

 

and

 

MAX

 

values

 

in

 

order,

 

then

 

return

 

the

 

meter

 

to

 

normal

 

mode

 

(Fig.2).

 

 

During

 

normal

 

operation

 

or

 

while

 

viewing

 

MIN/MAX

 

levels,

 

press

 

and

 

hold

 

the

 

RESET

 

key

 

for

 

more

 

than

 

1

 

second

 

to

 

clear

 

the

 

stored

 

minimum

 

and

 

maximum

 

values.

 

 

 

 

 

 

 

 

 

HIGH

 

CO2

 

ALARM

 

ALARM

 

The

 

meter

 

features

 

an

 

audible

 

alarm

 

that

 

warns

 

the

 

user

 

when

 

the

 

CO2

 

concentration

 

exceeds

 

the

 

programmed

 

limit.

 

Users

 

can

 

set

 

2

 

limits:

 

a

 

CO2

 

level

 

that

 

requires

 

ventilation

 

(See

 

P1.

3

 

in

 

setup

 

for

 

setting

 

alarm

 

limits)

 

and

 

a

 

lower

 

CO2

 

level

 

when

 

ventilation

 

is

 

no

 

longer

 

required

 

(See

 

P1.

2

 

in

 

setup

 

CO2

 

normal

 

limit).

 

 

During

 

high

 

alarm,

 

the

 

meter

 

emits

 

an

 

80dB

 

beep

 

and

 

displays

 

the

 

fan

 

icon

 

on

 

the

 

LCD.

 

The

 

alarm

 

can

 

be

 

temporarily

 

stopped

 

by

 

pressing

 

any

 

button,

 

or

 

it

 

will

 

automatically

 

stop

 

when

 

the

 

CO2

 

level

 

falls

 

below

 

the

 

lower

 

limit.

   

 

If

 

the

 

alarm

 

is

 

temporarily

 

silenced,

 

it

 

will

 

resume

 

if

 

the

 

CO2

 

level

 

fall

 

below

 

the

 

lower

 

limit

 

then

 

rises

 

above

 

the

 

upper

 

limit

 

again,

 

or

 

if

 

the

 

RESET

 

button

 

is

 

pressed

 

to

 

re

activate

 

the

 

alarm.

 

 

Summary of Contents for AZ-0004

Page 1: ...N POWER ON OFF Plug the wall adaptor into an appropriate receptacle The meter will turn on automatically after a short beep The lit LED indicates full power If the voltage is too high or low bAt will display on the LCD and the LED will flash Please see page 14 for trouble shooting During normal operation the LCD will display the current CO2 level in ppm air quality level air temperature humidity a...

Page 2: ...an be set up to 5 000ppm the accuracy of the CO2 reading is only specified up to 2 000ppm Alarm values higher than 2 000ppm are for reference only and should not be used for personal safety P2 0 SET TEMPERATURE UNITS Hold down the SET button for at least 3 seconds to enter setup mode then press in P1 0 mode to access P2 0 to set the temperature scale Fig 9 Press SET again to show temperature in o ...

Page 3: ...esh dry outdoor air when CO2 levels are approximately 400 ppm Do not calibrate during rainy days High humidity will affect the CO2 levels in air During manual calibration avoid placing the meter in areas crowded with people or close to structures that might give off CO2 like air ventilation pipes chimneys or automobiles To manually calibrate the meter place it outdoors and turn it on for at least ...

Page 4: ...Make sure you secure the unit inside the package properly to prevent any damage during transit that could void your device s warranty Finally please ship your device to the address shown under the Contact Us section below CO2Meter will not under any circumstances be responsible for your shipment expenses and no refund will be issued for shipping charges necessary for you to ship the unit to us Lia...

Reviews: