background image

2

 

 

The

 

fan

 

icon

 

remains

 

flashing

 

even

 

if

 

the

 

beeps

 

are

 

silenced.

 

The

 

icon

 

only

 

stops

 

flashing

 

when

 

the

 

CO2

 

level

 

fall

 

below

 

the

 

lower

 

limit

 

(Fig.3)

 

 

 

 

 

 

 

 

 

SETUP

 

There

 

are

 

4

 

setup

 

modes:

 

P1

CO2

 

alarm

 

levels,

 

P2

temperature

 

(C

 

or

 

F),

 

P3

date/time,

 

and

 

P4

factory

 

reset.

 

When

 

you

 

press

 

“SET”

 

the

 

setup

 

mode

 

will

 

be

 

shown

 

in

 

the

 

lower

 

right

 

corner

 

of

 

the

 

screen.

 

 

To

 

enter

 

setup,

 

while

 

in

 

normal

 

mode,

 

hold

 

down

 

the

 

SET

 

button

 

for

 

3

 

seconds.

 

To

 

exit

 

setup,

 

press

 

ESC

 

while

 

P1.

0

,

 

P2.

0

,

 

P3.

0

,

 

or

 

P4.

0

 

is

 

displayed.

 

 

P1.

1

 

SET

 

CO2

 

GOOD

 

LEVEL

 

Press

 

SET

 

to

 

display

 

P1.

0

 

and

 

”CO2”

 

(Fig.4)

 

on

 

the

 

LCD.

 

Press

 

SET

 

again

 

to

 

set

 

the

 

CO2

 

GOOD

 

level.

 

The

 

current

 

set

 

value

 

will

 

be

 

blinking

 

on

 

LCD

 

(Fig.5).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press

 

 

to

 

increase

 

or

 

MIN/MAX

 

to

 

decrease

 

the

 

value.

 

The

 

GOOD

 

alarm

 

range

 

is

 

from

 

0

 

to

 

700ppm

 

in

 

100ppm

 

increments.

 

Once

 

the

 

preferred

 

CO2

 

level

 

is

 

selected,

 

press

 

SET

 

to

 

continue

 

on

 

to

 

P1.

2

 

to

 

set

 

the

 

NORMAL

 

level

 

(Fig.6

 

)

 

or

 

press

 

ESC

 

to

 

return

 

to

 

P1.

0

 

without

 

saving

 

changes.

 

 

P1.

2

 

SET

 

CO2

 

NORMAL

 

LEVEL

 

P1.

2

 

is

 

the

 

upper

 

limit

 

of

 

the

 

CO2

 

NORMAL

 

level.

 

The

 

current

 

value

 

will

 

flash

 

on

 

the

 

LCD

 

(Fig.6).

 

Press

 

 

to

 

increase

 

or

 

MIN/MAX

▼” 

to

 

decrease

 

the

 

value.

 

The

 

NORMAL

 

level

 

can

 

be

 

set

 

between

 

700

 

and

 

1,000ppm.

 

Once

 

the

 

preferred

 

value

 

is

 

selected,

 

press

 

SET

 

to

 

save

 

P1.

2

 

and

 

continue

 

on

 

to

 

set

 

the

 

P1.

3

 

POOR

 

+

 

ALARM

 

threshold

 

setting

 

(Fig.7)

 

or

 

press

 

ESC

 

to

 

return

 

to

 

P1.

0

 

without

 

saving

 

changes.

 

 

 

P1.

3

 

SET

 

CO2

 

POOR

 

LEVEL

 

+

 

ALARM

 

P1.

3

 

is

 

used

 

to

 

set

 

the

 

CO2

 

alarm

 

threshold.

 

The

 

current

 

set

 

value

 

will

 

blink

 

on

 

the

 

LCD

 

(Fig.7).

 

Press

 

 

to

 

increase

 

or

 

MIN/MAX

 

to

 

decrease

 

the

 

value.

 

The

 

POOR

 

level

 

can

 

be

 

set

 

between

 

1,000

 

to

 

5,000ppm.

 

Press

 

SET

 

 

to

 

confirm

 

P1.

3

 

and

 

continue

 

to

 

P1.

4

 

(Fig.8)

 

or

 

press

 

ESC

 

without

 

saving

 

to

 

return

 

to

 

P1.

0

 

 

 

 

 

 

 

 

P1.

4

 

SET

 

ALARM

 

ON/OFF

 

P1.

4

 

is

 

used

 

to

 

set

 

alarm

 

on

 

and

 

off.

 

When

 

entering

 

P1.

4

,

 

the

 

default

 

“On“

 

will

 

be

 

blinking

 

on

 

the

 

LCD

 

(Fig.8).

   

 

Press

 

 

or

 

MIN/MAX

 

to

 

switch

 

the

 

alarm

 

to

 

“Off“.

 

Then

 

press

 

SET

 

 

to

 

confirm

 

P1.

4

 

and

 

return

 

to

 

P1.

0

 

(Fig.4)

 

or

 

press

 

ESC

 

to

 

return

 

to

 

P1.

0

 

without

 

saving.

 

 

CAUTION:

 

Although

 

the

 

TIM10

 

alarm

 

can

 

be

 

set

 

up

 

to

 

5,000ppm,

 

the

 

accuracy

 

of

 

the

 

CO2

 

reading

 

is

 

only

 

specified

 

up

 

to

 

2,000ppm.

 

Alarm

 

values

 

higher

 

than

 

2,000ppm

 

are

 

for

 

reference

 

only

 

and

 

should

 

not

 

be

 

used

 

for

 

personal

 

safety.

 

 

P2.

0

 

SET

 

TEMPERATURE

 

UNITS

 

Hold

 

down

 

the

 

“SET”

 

button

 

for

 

at

 

least

 

3

 

seconds

 

to

 

enter

 

setup

 

mode,

 

then

 

press

 

 

in

 

P1.

0

 

mode

 

to

 

access

 

P2.

0

 

to

 

set

 

the

 

temperature

 

scale

 

(Fig.9).

 

Press

 

SET

 

again

 

to

 

show

 

temperature

 

in

 

o

C

 

or

 

o

F

 

on

 

the

 

display

 

(Fig.

 

10).

 

Press

 

 

or

 

MIN/MAX

 

to

 

change

 

units,

 

then

 

press

 

SET

 

 

to

 

save

 

or

 

ESC

 

to

 

exit

 

without

 

saving

 

and

 

return

 

to

 

P2.

0

 

 

 

 

 

 

 

P3.

0

 

SET

 

REAL

 

TIME

 

CLOCK

 

The

 

TIM10

 

can

 

display

 

time

 

in

 

either

 

24

 

hour

 

or

 

12

 

hour

 

(am/pm)

 

format.

 

Hold

 

down

 

the

 

“SET”

 

button

 

for

 

at

 

least

 

3

 

seconds

 

to

 

enter

 

setup

 

mode,

 

then

 

press

 

 

twice

 

to

 

access

 

the

 

P3.

0

 

real

time

 

clock

 

(rtc)

 

setup

 

(Fig.11).

 

 

To

 

start,

 

press

 

SET

 

 

to

 

display

 

P3.

1

 

with

 

“rtc”

 

and

 

the

 

blinking

 

year

 

digits

 

(Fig.12)

 

in

 

the

 

lower

 

left

 

corner

 

of

 

the

 

display.

 

To

 

change

 

the

 

year,

 

press

 

 

or

 

MIN/MAX

 

to

 

change

 

the

 

value,

 

then

 

press

 

SET

 

 

to

 

save

 

the

 

year

 

and

 

continue,

 

or

 

press

 

ESC

 

 

to

 

exit

 

without

 

saving.

   

 

 

 

 

 

 

 

Continue

 

to

 

press

 

SET

 

to

 

change

 

to

 

the

 

month,

 

and

 

then

 

the

 

day.

 

After

 

you

 

press

 

SET

”,

 

press

 

 

or

 

MIN/MAX

 

while

 

the

 

year,

 

month

 

or

 

day

 

values

 

are

 

flashing

 

to

 

set

 

the

 

correct

 

date.

 

Press

 

SET

 

to

 

save

 

and

 

move

 

forward

 

to

 

set

 

the

 

time,

 

or

 

press

 

ESC

 

 

to

 

return

 

to

 

P3.

0

 

mode

 

without

 

saving.

 

 

To

 

set

 

the

 

clock,

 

in

 

P3.

4

 

mode

 

with

 

the

 

hours

 

flashing,

 

press

 

 

or

 

MIN/MAX

 

to

 

change

 

from

 

12

 

to

 

24

 

hour

 

time

 

format

 

(Fig11).

 

Press

 

SET

 

to

 

save

 

and

 

move

 

forward

 

to

 

P3.

5

 

mode

 

to

 

set

 

the

 

time,

 

or

 

press

 

ESC

 

 

to

 

return

 

to

 

P3.

0

 

mode

 

without

 

saving.

 

 

 

 

 

 

 

 

While

 

in

 

P3.

5

 

mode,

 

the

 

current

 

hour

 

setting

 

will

 

blink

 

(Fig.14).

 

To

 

change

 

the

 

setting,

 

press“

 

or

 

MIN/MAX

 

to

 

adjust

 

the

 

time.

 

Press

 

SET

 

to

 

save

 

the

 

setting

 

or

 

press

 

ESC

 

 

to

 

return

 

to

 

P3.

0

.mode

 

without

 

saving.

 

 

P4.

0

 

RESET

 

Hold

 

down

 

the

 

“SET”

 

button

 

for

 

at

 

least

 

3

 

seconds

 

to

 

enter

 

setup

 

mode,

 

then

 

press

 

 

3

 

times

 

to

 

access

 

P4.

0

 

mode

 

to

 

revert

 

the

 

meter

 

to

 

the

 

factory

 

default

 

state

 

(Fig.15).

 

 

Press

 

SET

 

to

 

go

 

to

 

P4.

1

 

mode.

 

“No”

 

will

 

be

 

blinking

 

on

 

the

 

display

 

(Fig.16).

 

Press

 

▲” 

or

 

MIN/MAX

 

to

 

change

 

to

 

“Yes”,

 

then

 

press

 

SET

 

 

to

 

save

 

the

 

setting.

 

Press

 

ESC

 

to

 

return

 

to

 

P4.

0

C

 

without

 

saving.

 

 

 

 

 

 

 

 

 

If

 

you

 

choose

 

“Yes”,

 

the

 

meter

 

is

 

reset

 

to

 

the

 

following

 

factory

 

defaults:

 

 

 

 

 

 

 

 

Summary of Contents for AZ-0004

Page 1: ...N POWER ON OFF Plug the wall adaptor into an appropriate receptacle The meter will turn on automatically after a short beep The lit LED indicates full power If the voltage is too high or low bAt will display on the LCD and the LED will flash Please see page 14 for trouble shooting During normal operation the LCD will display the current CO2 level in ppm air quality level air temperature humidity a...

Page 2: ...an be set up to 5 000ppm the accuracy of the CO2 reading is only specified up to 2 000ppm Alarm values higher than 2 000ppm are for reference only and should not be used for personal safety P2 0 SET TEMPERATURE UNITS Hold down the SET button for at least 3 seconds to enter setup mode then press in P1 0 mode to access P2 0 to set the temperature scale Fig 9 Press SET again to show temperature in o ...

Page 3: ...esh dry outdoor air when CO2 levels are approximately 400 ppm Do not calibrate during rainy days High humidity will affect the CO2 levels in air During manual calibration avoid placing the meter in areas crowded with people or close to structures that might give off CO2 like air ventilation pipes chimneys or automobiles To manually calibrate the meter place it outdoors and turn it on for at least ...

Page 4: ...Make sure you secure the unit inside the package properly to prevent any damage during transit that could void your device s warranty Finally please ship your device to the address shown under the Contact Us section below CO2Meter will not under any circumstances be responsible for your shipment expenses and no refund will be issued for shipping charges necessary for you to ship the unit to us Lia...

Reviews: