8
Preventive Maintenance and Troubleshooting Guide
GSE
®
recommends that you perform the following service to minimize unexpected downtime for your
compressor:
Replace the connecting rods or piston cups and sleeves
Replace the flapper valves
Replace the head O-ring Head gasket.
Replace the valve plate O-rings
If you are having a problem with your compressor, use this table to help determine the cause(s):
Problem
Low
Flow
Low
Pressure
Unit Will
Not Start
Motor
①
Overheats
Loud
Unit
Possible Cause
Corrective Action
×
High voltage at compressor Reduce voltage
×
×
×
×
Low voltage at compressor
Increase voltage
×
×
×
Damaged valves
Replace flapper valves
×
×
×
Debris in valves
Remove debris and check for valve
damage
×
×
×
Damaged gaskets
Replace gaskets
×
×
×
Worn Cup
Replace connecting rod
×
×
×
Loose head screws
Tighten head screws
×
Broken fan
Replace fan
×
×
×
Bent motor shaft
Replace entire unit
×
×
Damaged capacitor
Replace capacitor
×
Loose fittings
Tighten fittings
×
×
Insufficient ventilation in
enclosure
Increase air circulation to enclosure
×
×
Worn bearings
Replace Eccentric Bearing assembly
①
Thermal protector in motor will interrupt current when motor overheats.