4.1.6 Read message
This command reads the error message saved in the terminal.
Byte
Command
Response
01
STX
STX
02
Node
Node
03
0x08
0x0
StatusBit
04
CmdGetAlarm
CmdGetAlarm
05
0x00
0x00
06
0x00
High byte of message code
07
0x00
Low byte of message code
08
CRC
CRC
09
ETX
ETX
Example:
To read the message in the terminal at node address 0, encoded 0x4003 (alarm for
incorrect command received).
Byte
Command
Response
01
0x02
(STX)
0x02
(STX)
02
0x00
(Node)
0x00
(Node)
03
0x08
0x0
StatusBit
(0x00)
04
0x48
(CmdGetAlarm)
0x48
(CmdGetAlarm)
05
0x00
0x00
06
0x00
0x40
(
High byte of message code
)
07
0x00
0x03
(
Low byte of message code
;
[0x1b 0xfc]=0x03)
08
0xbf
(CRC)
0xf4
(CRC)
09
0x03
(ETX)
0x03
(ETX)
Summary of Contents for RM85x