4.3
TORCH VOLTAGE
NOTE:
It is preferable to use the divided voltage instead of the torch voltage. The Torch voltage can be very
high and there could be many safety implications in wiring this to the controller. The high voltage
could also be a possible source of noise. Use it as a last resource.
4.4
OUTPUT SIGNALS
Voltage applied can be from 5 to 80VDC@50mA, outputs signal optoisolated Open Collector.