2.2 Technical Specifications
2.2.1 Technical Specifications
Specs
Values
BAT Input Voltage Range (VDC)
24VDC
(
20VDC-30VDC
)
/ 48VDC (40VDC-60VDC)
Output Power (W)
2000W/3000W/5000W
AC Output Voltage (VAC)
100V ~250V(Adjustable)
AC Input Voltage (VAC)
100V/110VC/220V/230V
AC Output Frequency (HZ)
50HZ/60HZ(Adjustable)
AC Input Frequency (HZ)
50HZ/60HZ
Pure sine wave Regulation
(
THD
)
%
≤3%
(
Liner Load
)
Inverter Efficiency
(
η
)
%
≥90%
Over load
110% ≤30S / 150% ≤1S
PV Panel Max Input Voltage
(
VDC)
150V
PV Panel Min Input Voltage
(
VDC)
24V
(
36VDC) / 48V
(
72VDC
)
PV Panel Max Input Power (W)
24V
(
1800W) / 48V
(
3600W) – varies by model
MPPT Charging Current (A)
40A/60A – varies by model
Grid Charging Current (A)
15A/25A – varies by model
Dielectric Strength
1500VAC 5mA 1min
Ambient Temperature (
℃
)
-20
℃
to 55
℃
(-4
°
F to 131
°
F)
Humidity
90% RH Non-condensing
Altitude (m
)
≤3000m (≤9800ft)
3.Operation and Installation
3.1 Operation
3.1.1 Open
Before delivery, this equipment has been strictly tested and inspected. To ensure the inverter
was not damaged in transit, please inspect it thoroughly. If any equipment is damaged, contact the
supplier immediately. Make sure the following items are present:
Complete Inverter Body
User’s Manual
Warranty Card
Certificates
Other accessories and components