6D.  Quartz Tube Removal and Cleaning

CAUTION

 

Wear proper eye and skin protection for servicing 

glass components.

NOTICE

 

Damage caused by broken quartz tubes is not covered 

under the DEL UV Spa Limited Warranty.

CAUTION

 

If broken glass is trapped in the spa system, do not 

operate the spa. Contact a service professional to have the glass 

removed.

i.  Make sure the spa is shut down and the system has cooled     

before performing maintenance on the quartz tube. If you 

have installed isolation valves, close them before servicing. 

If you do not have isolation valves, the spa must be drained 

below where the DEL UV Spa is mounted.

ii.  Remove the enclosure cover and UV lamp as described in 

Section 6A and set aside.

iii.  Remove the two retainer screws and retainer washer from the 

top of the lamp retainer and pull the lamp retainer out of the 

UV chamber cap. 

NOTICE

 

Any water remaining in the system above the level of the

DEL UV Spa will flow out of the UV housing once the lamp retainer is 

removed.

iv.  Grasp the inside of the quartz tube and pull it out of the 

housing. Make sure the sealing ring does not get lost during 

quartz tube removal.

v.  Inspect the quartz tube for cracks and replace if cracks are 

found. Inspect the sealing ring for nicks or hardness and 

replace if necessary.

vi.  Clean the quartz tube exterior with a mild solution of muriatic 

acid and water in a ratio of four parts water to one part acid 

(4:1). DO NOT USE ABRASIVE CLEANERS. 

CAUTION

 Follow the directions for safe use and handling of

muriatic acid on the acid bottle label. When mixing, always add acid 

to container first, then add water. 

SECTION 2 Maintenance Instructions

Summary of Contents for DEL UV SPA

Page 1: ...TY INFORMATION READ AND FOLLOW ALL INSTRUCTIONS Save these instructions Leave manual with homeowner after installation Improper installation adjustment alteration service or lack of maintenance can ca...

Page 2: ...ed by a Ground Fault Circuit Interrupter G F C I If the DEL UV Spa is connected to an independent electrical supply then a G F C I must be installed between the DEL UV Spa and the electrical supply WA...

Page 3: ...c UV Reactor Service Maintenance 7 d Quartz Tube Removal Cleaning 8 e Quartz Tube Installation 9 f Standard Replacement Parts List 9 SUPPORT 10 DIAGRAMS SHOWN IN THESE INSTRUCTIONS page 4 DEL UV SPA S...

Page 4: ...plication other than a portable spa 2 Mounting a Use the two mounting holes located internally on the back panel of the DEL UV Spa Figure 1 b Mount the DEL UV Spa to the spa frame with 8 hardware The...

Page 5: ...either direction Temporarily apply power to the spa and start the spa circulation system to check for and repair any water leaks Disconnect power to the spa Water Return to Spa Water from Spa Isolati...

Page 6: ...ing the power cord parallel to any low voltage signal wires c Use a minimum 8 AWG solid copper conductor to connect the bonding lug provided on the enclosure base to the spa equipment ground 5 Operati...

Page 7: ...HANDS Handle the lamp carefully and set aside If discarding dispose of properly see the following note NOTICE UV Lamp CONTAINS MERCURY Manage in accordance with disposal laws See www lamprecycle org 6...

Page 8: ...he two retainer screws and retainer washer from the top of the lamp retainer and pull the lamp retainer out of the UV chamber cap NOTICE Any water remaining in the system above the level of the DEL UV...

Page 9: ...and tighten the lamp retainer screws until the lamp retainer is completely seated against the UV chamber cap iv After spa is refilled turn the spa ON and check the seal around the lamp retainer for l...

Page 10: ...__________________ System Purchased From _____________________________________________ Installation Date _____________________________ Serial Number _______________________________ Model Number ______...

Page 11: ...11 NOTES...

Page 12: ...CMP LLC 36 HERRING ROAD NEWNAN GA 30265 WWW C M P COM DEL 4 2769 01 Rev B_0921ab...

Reviews: