background image

5

3. Plumbing

Make appropriate water tight connections on both the inlet and outlet 

of the DEL UV Spa. Water flow may be in either direction. 

Temporarily apply power to the spa and start the spa circulation 

system to check for and repair any water leaks. Disconnect power to 

the spa.

1. Overview

Achieve The Complete Modern Spa® by choosing sanitizing 

components that work together, creating the best possible installation. 

The DEL UV

®

 Spa is a UV sanitizer designed for use in portable spas 

and to be controlled by the spa’s equipment pack. Please contact 

customer support if the DEL UV

®

 Spa is used in an application other 

than a portable spa. 

 

 

 

 

2. Mounting

a.  Use the two mounting holes located internally on the back panel of 

the DEL UV Spa (Figure 1).

b. Mount the DEL UV Spa to the spa frame with #8 hardware. The 

preferred mounting orientation is shown in Figure 2. Connect water 

inlet at the bottom. Contact customer support for other installation 

options.

Mounting Holes

Water Outlet

Bonding Lugs

Allow Vertical Clearance

for Lamp Removal

(approx. 12”)

Water Intlet

Water Return to Spa

Water from Spa

Isolation Valve

(Recommended)

Isolation Valve

(Recommended)

SECTION 1 Installation Instructions

Figure 2: DEL UV® Spa Plumbing Diagram

Summary of Contents for DEL UV SPA

Page 1: ...TY INFORMATION READ AND FOLLOW ALL INSTRUCTIONS Save these instructions Leave manual with homeowner after installation Improper installation adjustment alteration service or lack of maintenance can ca...

Page 2: ...ed by a Ground Fault Circuit Interrupter G F C I If the DEL UV Spa is connected to an independent electrical supply then a G F C I must be installed between the DEL UV Spa and the electrical supply WA...

Page 3: ...c UV Reactor Service Maintenance 7 d Quartz Tube Removal Cleaning 8 e Quartz Tube Installation 9 f Standard Replacement Parts List 9 SUPPORT 10 DIAGRAMS SHOWN IN THESE INSTRUCTIONS page 4 DEL UV SPA S...

Page 4: ...plication other than a portable spa 2 Mounting a Use the two mounting holes located internally on the back panel of the DEL UV Spa Figure 1 b Mount the DEL UV Spa to the spa frame with 8 hardware The...

Page 5: ...either direction Temporarily apply power to the spa and start the spa circulation system to check for and repair any water leaks Disconnect power to the spa Water Return to Spa Water from Spa Isolati...

Page 6: ...ing the power cord parallel to any low voltage signal wires c Use a minimum 8 AWG solid copper conductor to connect the bonding lug provided on the enclosure base to the spa equipment ground 5 Operati...

Page 7: ...HANDS Handle the lamp carefully and set aside If discarding dispose of properly see the following note NOTICE UV Lamp CONTAINS MERCURY Manage in accordance with disposal laws See www lamprecycle org 6...

Page 8: ...he two retainer screws and retainer washer from the top of the lamp retainer and pull the lamp retainer out of the UV chamber cap NOTICE Any water remaining in the system above the level of the DEL UV...

Page 9: ...and tighten the lamp retainer screws until the lamp retainer is completely seated against the UV chamber cap iv After spa is refilled turn the spa ON and check the seal around the lamp retainer for l...

Page 10: ...__________________ System Purchased From _____________________________________________ Installation Date _____________________________ Serial Number _______________________________ Model Number ______...

Page 11: ...11 NOTES...

Page 12: ...CMP LLC 36 HERRING ROAD NEWNAN GA 30265 WWW C M P COM DEL 4 2769 01 Rev B_0921ab...

Reviews: