5
INSTALLATION
INSTALLING THE NEW OZONE GENERATOR SUBASSEMBLY
1. Install the new ozone generator subassembly using the screws previously removed.
2. Mount the terminal block to the new ozone bracket using the screws previously removed.
NOTICE
The new terminal block position is lower than previous – the unit wire harness will allow it
to reach but it may require adjustment and/or removal of zip-ties.
3. Connect the new ozone module power connectors (3) to any of the six available positions on the
wire harness.
4. Connect the new longer ozone gas line to the injector tube adapter and secure with tubing clamp.
The ozone gas line contains a check valve – install so that the arrow on the check valve
points towards the injector tube adapter.
5. Connect the other end of the ozone gas line to the bottom of the ozone outlet manifold and secure
with tubing clamp.
SYSTEM STARTUP
Restore power to the unit and check proper operation, including no water leaks from the ozone gas line
and verify the ozone module lights (3) are illuminated.
Close unit door.
NOTICE
FIGURE 2: NEW OZONE GENERATOR SUBASSEMBLY
Power
Connectors
Ozone
Module
Ozone
Module
Lights
Ozone Outlet
Manifold
Ozone Gas
Line
Tubing
Clamp