background image

 

Owner’s Manual

 

ULTRA-POWER II
ACCU-POWER &
ACCU-POWER ONBOARD
Solid State Fully 
Automatic Chargers

 

Manual Number 1017361 

Edition Code 0493B0101A

Summary of Contents for ACCU-POWER

Page 1: ...Owner s Manual ULTRA POWER II ACCU POWER ACCU POWER ONBOARD Solid State Fully Automatic Chargers Manual Number 1017361 Edition Code 0493B0101A...

Page 2: ...connect the charger to battery packs that are not compatible with the DC output voltage specified on the charger Overheating and transformer burnout will result Do not use the charger if the plug cord...

Page 3: ...onsult your local HVAC engineer Do not use near fuels grain dust solvents thinners or other flammables Chargers can ignite flammable materials and vapors Keep the charger dry Do not expose it to rain...

Page 4: ...t allow the charger to operate for more than 30 minutes at 23 amperes or more If the batteries are heavily discharged and the AC input line voltage is higher than normal the initial charge may exceed...

Page 5: ...racteristics and may never light the full range light but will still give good performance In this case all voltages will be lower For example one light will give an estimated 36 hole performance and...

Page 6: ...ON then there may have been a power interruption dur ing the charging cycle Consult your local Club Car Distributor Dealer to further analyze the problem The lights allow you to spot potential problem...

Page 7: ...er TROUBLESHOOTING GUIDE DANGER Do not disassemble the charger Take it to a qualified service technician when service or repair is required Incorrect assembly may result in fire or electrical shock Al...

Page 8: ...shortly If the click cannot be heard remove the AC plug from the outlet Connect the AC power supply cord of a stationary charger known to be operating properly to a live AC outlet Connect the DC outpu...

Page 9: ...the same AC outlet If the AC fuse circuit breaker still blows have a qualified electrician check for weak line fuse circuit breaker If the AC line fuse circuit breaker works properly with the second c...

Page 10: ...rking on or around electrical devices Transportation expenses for warranty services are also excluded from this warranty WARRANTY LIMITATIONS CLUB CAR s liability under this limited warranty or in any...