USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 7 of 14
Pump
Operation with the digital inputs
The digital inputs can be operated in Manual or Timer
mode.
They have the highest priority level: they act as
MASTER over all the functions currently in use.
Only the Run/Stop and DISP/FUNC buttons remain
active.
When a digital input is used, the LED associated with
the speed in question blinks rapidly
(DI1 = V1, DI2 = V2 or DI3 = V3).
To obtain an action through the digital inputs, the DI4
input must be closed.
DI4
Run/Stop Closed
If several digital inputs are switched simultaneously,
only one will be carried out in the order of priority
specified in the table opposite.
DI1 = V1
DI2 = V2
DI3 = V3
DI1 = V1
V1
V2
V3
DI2 = V2
V2
V2
V3
DI3 = V3
V3
V2
V3
N.B.
Once the action associated with the digital input is complete (open contact),
the filtration pump resumes the action for the current operational mode.
If the DI4 digital inlet is open, the filtration pump will
not start and dSTOP will be displayed on the pump's
screen.
• Close the DI4 inlet.
• If necessary press RUN/STOP to start the filtration
pump.
DI1
DI2
DI3
DI4
C
dStoP
A
or
Summary of Contents for Hayward RS3016VSTD
Page 18: ... 172 HAYWARD 1 3 2 6 11 8 9 10 12 13 14 15 18 4 5 7 6 19 17 20 16 SP2310VSTD SP2315VSTD ...
Page 20: ... 174 HAYWARD 1 3 2 6 11 8 9 10 12 13 14 15 16 4 5 7 6 7 17 18 19 SP2715VSTD ...
Page 22: ... 176 HAYWARD SP2616VSTD ...
Page 24: ... 178 HAYWARD RS3016VSTD RS3020VSTD SP3016VSTD SP3020VSTD ...
Page 27: ...Hayward is a registered trademark of Hayward Industries Inc 2017 Hayward Industries Inc ...