background image

 WARNING

FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed 

and qualified in pool equipment by the jurisdiction in which the product will be installed where such 

state or local requirements exist. The maintainer must be a professional with sufficient experience 

in pool equipment installation and maintenance so that all of the instructions in this manual can be 

followed exactly. Before installing this product, read and follow all warning notices and instructions 

that accompany this product. Failure to follow warning notices and instructions may result in property 

damage, personal injury, or death. Improper installation and/or operation may void the warranty. 

 

DO NOT MODIFY THIS EQUIPMENT.
Improper installation and/or operation can create unwanted electrical hazard which 

can cause serious injury, property damage, or death. 
ATTENTION INSTALLER - This manual contains important information about the 

installation, operation and safe use of this product. This information should be given 

to the owner/operator of this equipment.

H0771400_REV

A

INSTALLATION AND 

OPERATION MANUAL

ENGLISH  |  FRANÇAIS  |  ESPAÑOL

Jandy Laminar Jet

JLLED4C Series

JLFBR Series 

Summary of Contents for Laminar Jet JLFBR Series

Page 1: ...d instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Improper installation and or operation may void the...

Page 2: ...stallation 9 4 2 Installing the Laminar Jet with LED Light 9 4 3 Wiring Options for Controlling Laminar Jet with LED Lights 10 4 4 Twelve 12 Volt Transformer Installation 11 Section 5 Laminar Jet with...

Page 3: ...Failure to follow safety warnings and instructions can result in severe injury death or property damage Visit www jandy com or call 800 822 7933 888 647 4004 Canada for additional free copies of these...

Page 4: ...stalled and secured before testing RELEASE ALL AIR in the system before testing Water pressure for test must NOT EXCEED 35 PSI Water temperature for test must NOT EXCEED 100 F 38 C Limit test to 24 ho...

Page 5: ...ure psi 9 5 10 3 11 Height of Jet ft m 5 1 5 6 1 8 7 2 1 2 3 Plumbing Each laminar jet requires a 1 to 2 in 38 50 mm PVC main feed line with 1 in 25 mm PVC entering the deck canister A check valve is...

Page 6: ...5 2 50 8 1 38 1 25 4 2 50 8 6 2 50 8 1 38 1 25 4 2 50 8 B Plumbing Loop C Inlet Lines to Laminar Jet Deck Canister Maximum 6 Lines per Plumbing Loop D Bypass Bleed Off Line A Main Feed Line Check Val...

Page 7: ...r dimensions Deck Canister Water Output Deck Canister Lid with Slot Deck Material Deck Material Laminar Jet Assembly Deck Canister Lid Adjustable Collar 1 25 4 mm Laminar Jet Water Supply 1 38 mm Drai...

Page 8: ...iameter 60 cm deep 45 cm diameter This will ensure enough room for positioning the canister and laying out the plumbing The dimensions allow for the addition of a layer of pea gravel about 1 8 to 1 4...

Page 9: ...must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances Improper installa...

Page 10: ...es may be used to control the on off and color functions of each laminar jet with LED light and color functions of each laminar jet with LED light It is recommended that these switches be located next...

Page 11: ...Do not cut the fiber ends too close to the taped edge Leave a inch 6 mm distance between the cable end and the end of the taped edge This will prevent adhesive on the tape from melting and getting on...

Page 12: ...e angle can be adjusted approximately 10 6 The laminar jet is installed on two 2 pivots Loosen the locking screws to adjust the jet angle Once you are satisfied with the angle and location of the jet...

Page 13: ...te a more intense light 1 Use the light intensity adjustment screw attached to the scratcher to adjust the light intensity 2 To increase the light intensity turn the screw counter clockwise to increas...

Page 14: ...y be removed to a storage location If left in the deck canister tape over the slot opening to ensure no water will enter the system If fiber optic cable is used be sure to remove the retaining nut on...

Page 15: ...Page 15 ENGLISH Jandy Laminar Jet Installation and Operation Manual ENGLISH 10 2 Exploded View 7 1 9 2 10 5 7 8 4 6 6 7 6 7 3 4 4 9 10...

Page 16: ...S A S U used under license All other trademarks are the property of their respective owners H0771400_REVA Zodiac Pool Systems LLC 2882 Whiptail Loop 100 Carlsbad CA 92010 Fluidra Group Australia Pty...

Page 17: ...ctives qui accompagnent ce produit Tout non respect des instructions d avertissement peut entra ner des dommages mat riels des blessures corporelles ou m me la mort Une mauvaise installation ou utilis...

Page 18: ...DEL 25 4 2 Installation de la fontaine Laminar avec clairage DEL 25 4 3 Options de c blage pour contr ler la fontaine Laminar avec clairage DEL 26 4 4 Installation du transformateur de douze 12 volts...

Page 19: ...uivre les mises en garde et les instructions pourrait entra ner des blessures corporelles graves la mort ou des dommages la propri t Visitez www jandy com ou composez 800 822 7933 888 647 4004 Canada...

Page 20: ...s sont correctement install s et fix s solidement avant d effectuer un test LIB RER TOUT L AIR du syst me avant d effectuer le test La pression d eau pour le test NE DOIT PAS EXC DER 35 PSI La temp ra...

Page 21: ...jet pi m 5 1 5 6 1 8 7 2 1 2 3 Tuyauterie Chaque fontaine Laminar n cessite une conduite d alimentation principale en PVC de 38 50 mm 1 2 po avec du PVC de 25 mm 1 po entrant dans la cartouche de pont...

Page 22: ...plomberie C Conduites d entr e la cartouche de fontaine Laminar Maximum 6 conduites par circuit de plomberie D Conduite de d rivation purge A Conduite d alimentation principale Soupape antiretour Robi...

Page 23: ...l de terrasse Ensemble de fontaine Laminar Collier de r glage de couvercle de cartouche de pont Alimentation d eau la fontaine Laminar 1 po 25 4 mm Conduite d vacuation 1 po 38 mm Conduit lectrique po...

Page 24: ...18 pouces de diam tre 60 cm profond 45 cm diam tre Cela garantira suffisamment d espace pour positionner la cartouche et disposer la plomberie Les dimensions permettent l ajout d une couche de gravier...

Page 25: ...r ou certifi ou un technicien de piscine qualifi conform ment au Code national de l lectricit et tous les codes et ordonnances locaux applicables Une installation inad quate g n rera des risques lectr...

Page 26: ...rs toujours synchronis es synchronis es Des interrupteurs s par s peuvent tre utilis s pour contr ler Des interrupteurs s par s peuvent tre utilis s pour contr ler les fonctions marche arr t et couleu...

Page 27: ...ine du c ble 2 l aide de ruban lectrique noir coller fermement la fibre expos e en laissant environ po 13 mm de fibre expos e l extr mit du c ble Le ruban emp che les fibres individuelles de se s pare...

Page 28: ...s le corps de la buse Ceci est normal et se produira jusqu ce que tout l air soit purg de la tuyauterie du syst me L air emprisonn peut galement provoquer une l g re distorsion de l action de l eau Il...

Page 29: ...s les interrupteurs simultan ment Toutes les lumi res Jandy WaterColors et les fontaines Laminar Jandy avec clairage DEL se synchroniseront automatiquement si elles sont activ es par le m me interrupt...

Page 30: ...ns qui n cessitent un hivernage 1 Retirer l assemblage du couvercle de la cartouche de pont et d visser le raccord de pouce 13 mm 2 Visser le capuchon sur le tuyau flexible fix la cartouche de pont La...

Page 31: ...Page 31 ENGLISH Jandy Fontaine Laminar Manuel d installation et de fonctionnement Fran ais 10 2 Vue clat e 7 1 9 2 10 5 7 8 4 6 6 7 6 7 3 4 4 9 10...

Page 32: ...ilis e sous licence Toutes les autres marques sont la propri t de leurs propri taires respectifs H0771400_REVA Zodiac Pool Systems LLC 2882 Whiptail Loop 100 Carlsbad CA 92010 Fluidra Group Australia...

Page 33: ...visos de advertencia y las instrucciones que se proporcionan con el producto Si no se siguen los avisos de advertencia o las instrucciones es posible que se produzcan da os materiales lesiones persona...

Page 34: ...i n del jet laminar con luces LED 41 4 3 Opciones de cableado para controlar el jet laminar con luces LED 42 4 4 Instalaci n del transformador de 12 voltios 43 Secci n 5 Instalaci n del jet laminar co...

Page 35: ...s instrucciones es posible que se produzcan lesiones graves muerte o da os materiales Visite www jandy com o llame al 800 822 7933 888 647 4004 Canad para obtener copias gratuitas adicionales de estas...

Page 36: ...ntes de la prueba LIBERE TODO EL AIRE del sistema antes de la prueba La presi n de agua para la prueba NO DEBE EXCEDER los 35 PSI La temperatura del agua para la prueba NO DEBE EXCEDER los 100 F 38 C...

Page 37: ...r as Cada jet laminar requiere una l nea de alimentaci n principal de PVC de 1 a 2 in 38 a 50 mm con PVC de 1 in 25 mm que ingrese al cubo de la plataforma Tambi n se requiere una v lvula de retenci n...

Page 38: ...nexiones de tuber as C L neas de entrada al bote de la plataforma del jet laminar m ximo de 6 l neas por circuito de conexiones de tuber as D L nea de derivaci n purga A L nea de alimentaci n principa...

Page 39: ...ote de la plataforma con ranura Material de la plataforma Material de la plataforma Conjunto de jet laminar Cuello ajustable de la tapa del bote de la plataforma Suministro de agua de 1 25 4 mm del je...

Page 40: ...as de di metro 60 cm de profundidad 45 cm de di metro Esto asegurar que haya lugar suficiente para posicionar el cubo y tender las tuber as Las dimensiones permiten agregar una capa de gravilla de un...

Page 41: ...o certificado o una persona cualificada en el servicio de piscinas deben instalar este jet laminar con luces LED en conformidad con National Electrical Code y todos los c digos y todas las ordenanzas...

Page 42: ...interruptor para que los colores est n que los colores est n siempre siempre sincronizados sincronizados Es posible utilizar interruptores separados para controlar Es posible utilizar interruptores s...

Page 43: ...OTA No corte los extremos de la fibra demasiado cerca del borde de la cinta Deje una distancia de de pulgada 6 mm entre el extremo del cable y el extremo del borde de la cinta Esto evitar que el adhes...

Page 44: ...con agua 5 Para ajustar el ngulo del chorro mueva el jet laminar hacia arriba o hacia abajo a fin de aumentar o reducir el ngulo con la mano o con un destornillador en la ranura de ajuste NOTA El ngul...

Page 45: ...luces de Jandy WaterColors y todas las luces del jet laminar con luces LED Jandy se sincronizar n autom ticamente si se activan mediante el mismo interruptor No se requieren otros accesorios Secci n...

Page 46: ...el invierno El jet laminar puede prepararse para el invierno en las regiones que lo requieren 1 Extraiga el conjunto de la tapa del bote de la plataforma y desatornille la uni n de pulgada 13 mm 2 Enr...

Page 47: ...P gina 47 ESPA OL Jet laminar Jandy Manual de instalaci n y operaci n ESPA OL 10 2 Vista ampliada 7 1 9 2 10 5 7 8 4 6 6 7 6 7 3 4 4 9 10...

Page 48: ...l S A S U utilizada bajo licencia Todas las dem s marcas comerciales son propiedad de sus respectivos due os H0771400_REVA Zodiac Pool Systems LLC 2882 Whiptail Loop 100 Carlsbad CA 92010 Fluidra Grou...

Reviews: