background image

Updated on 18 March, 2010 

 

- 6 - 

 

4. INSTALLATION PROCEDURES 

A.

 

Install drip tray below faucet. 

B.

 

Thoroughly clean the dual float valve, the cooling tank and baffle. The dual float valve and baffle must be in 

exact place for proper cooling operation. 

CAUTION: IF THE COLD WATER BAFFLE IS REMOVED, COLD WATER WILL NOT BE FORMED NOR DISCHARGED. 

C.

 

Connect the supply water hose to cold water piping of the 

back of the product. 

-

 

Connect the supply water pipe to water inlet at the back 

of the product. 

-

 

Use potable water only. 

-

 

Acceptable supply water pressure is 20 ~ 100psi. 

-

 

Press reset button if cold water does not flow. 

-

 

Once all the requirements above are met, open the tap 

water valve. 

CAUTION: TO PREVENT PROPERTY DAMAGE DUE TO WATER LEAKAGE, SEEK INSPECTION BY PLUMBERS TO 
SEE  THE  WATER  PRESSURE  IS  LESS  THAN  100PSI  (690KPA)  BEFORE  YOU  CONNECT  THE  SUPPLY  WATER 
HOSE. 

D.

 

For hot water activation, stay holding down hot faucet handle until water flow is continuous and clear. 

E.

 

Place the hot water switch on the "ON" position. 

(Check the available power supply against the cooler specification plate to ensure correct electrical service.) 

F.

 

Cooler will be ready to serve you Cold & Hot water in 30 minute after installation. 

G.

 

Hot  Water  Safety  Faucet:  A  safety  faucet  deters  accidental  dispensing  of  water  by  toddlers.  (Korea,  US 

patented) 

CAUTION: WATER FROM HOT FAUCET IS EXTREMELY HOT AND MAY SCALD.

 

CAUTION: FAILURE TO ABIDE BY ABOVE PROCEDURE CAN CAUSE PHYSICAL DAMAGE ON THE COOLER.

 

 

5. STORAGE 

A.

 

Close off the adapter valve to cut flow from main water pipe. 

B.

 

Switch off hot water switch. 

C.

 

Unplug power cord. 

D.

 

Disconnect the water pipe from the product. 

E.

 

Drain hot water by opening faucet. Then, do the same on cold water faucet. 

F.

 

Place a bucket behind the drain pipe. By unscrewing the drain cap counter clockwise, drain the remaining 

water in the hot water tank. When tank is emptied, dry drain cap and end of drain pipe. Close draining pipe 

with cap. 

Summary of Contents for D14A

Page 1: ...Updated on 18 March 2010 1...

Page 2: ...ty precaution before servicing the watercooler 1 Check if an electric leakage occurs in the appliance 2 To prevent electric shock unplug prior to servicing 3 In case of testing with power on wear rubb...

Page 3: ...g COLD CONSUMPTION 105W TEMP CONTROL AUTO TANK Stainless Steel CAPACITY 3 8 h 10 HOT CONSUMPTION 440W 465W PROTECTOR Heat Limiter TEMP CONTROL Hot Control TANK Stainless Steel CAPACITY 7 5 h 85 ELECTR...

Page 4: ...t of high temperature and high pressure passing through the condenser and then turn into the liquid refrigerants of low temperature and low pressure conditions by passing through the capillary tubes T...

Page 5: ...rrent PTC Starter Starts up the motor of compressor Cold water baffle Separates the supplied water from cold water hot water or room temperature water respectively Hot tank heater Heats the supplied r...

Page 6: ...ater activation stay holding down hot faucet handle until water flow is continuous and clear E Place the hot water switch on the ON position Check the available power supply against the cooler specifi...

Page 7: ...Remove faucets from the product Both faucets are disassembled by turning them counter clockwise I Wear disposable gloves clean and safe material for drinking water J Wash the faucets the dual float v...

Page 8: ...sted properly Replace or adjust the thermostat as necessary The ambient temperature is high It is normal for the cooler to run continuously at high ambient temperatures C The cooler compressor runs co...

Page 9: ...ater system Identify the loose or broken wire connection repair as necessary The hot control is defective Replace the hot control The heat limiter is ON Push Reset button of heat limiter The hot tank...

Page 10: ...eakage through inside or outside of appliance The faucet is not completely connected Properly connect the faucet C Water drips from dual float valves assembly The dual float valves elbow union is defe...

Page 11: ...Updated on 18 March 2010 11...

Page 12: ...Updated on 18 March 2010 12...

Page 13: ...Updated on 18 March 2010 13...

Page 14: ...Updated on 18 March 2010 14...

Reviews: