background image

DM542S

USER MANUAL

www.cloudratmotor.com

6

3.4.3 Control signal wiring example

Common anode

Common cathode

Difference

Summary of Contents for DM542S

Page 1: ...DM542S USER MANUAL www cloudratmotor com DM542S USER MANUAL...

Page 2: ...1Port function description 3 3 2 Power supply input 3 3 3 Motor connection 4 3 4 Control signal connection 5 3 4 1 PUL DIR port connection for pulse command 5 3 4 2 ENA port used to enable or disable...

Page 3: ...rent protection Its input and output control signals are optically isolated Power supply 24 50VDC Output Current Up to 5 0 amps peak value Current control PID current control algorithm Micro stepping...

Page 4: ...tall the drive vertically or horizontally with its front facing forward top facing upward to facilitate cooling During assembly avoid drillings and other foreign matters falling inside the drive Durin...

Page 5: ...constant current control The drive output the voltage to motor by changing the input power into PWM chopping wave when it is working In this case the input power will affect the performance of drive...

Page 6: ...6 B B A A NC NC The matching motor of the DM 542S drive is the low resistance and low inductance hybrid stepper motor The common 2 phase stepper motor s lead number are 4 8 and 6 There is only one con...

Page 7: ...used to enable or disable When the default optocoupler is off the driver outputs current to the motor When the internal optocoupler is turned on the driver will cut off the current of each phase of t...

Page 8: ...DM542S USER MANUAL www cloudratmotor com 6 3 4 3 Control signal wiring example Common anode Common cathode Difference...

Page 9: ...to set current which is output from drive to motor Generally the current setting is the motor rated current If your system has high request to the heating please decrease the current properly to lowe...

Page 10: ...e motor stops Off means that when the drive power on pulse stops the driver switches the current output to the motor to half of the rotation half flow On indicates that the drive maintains the same cu...

Page 11: ...of motor is reverse Adjust the DIP SW5 The motor cable is disconnected Check the connection The motor has only one direction Pulse mode error or DIR port damaged Alarm indicator is on The motor conne...

Page 12: ...rantee Clause A 1 Warranty period 12 months We provide quality assurance for one year from the date of delivery and free maintenance service for our products during the warranty period A 2 Exclude the...

Reviews: