CXL-46T Installation Instructions v1.0

1

CXL-46T

100/70 V Transformer

 

Installation Instructions 

 

Important Safety Notes

It should be recognised that 100 V-line or 70 V-line speaker systems have the 
potential to deliver an electric shock. Install the CXL-46T only in accordance 

with these instructions.
In all cases, the external wiring and associated speakers will need to comply 

with local electrical regulations for AC voltages up to 100 V

rms

  (141 V

peak

).

Do not expose the transformer to rain or moisture.
The transformer module must be installed in a safe manner. 
Cloud Electronics Ltd. accept no responsibility for hazardous installations.

Summary of Contents for CXL-46T

Page 1: ...r an electric shock Install the CXL 46T only in accordance with these instructions In all cases the external wiring and associated speakers will need to comply with local electrical regulations for AC voltages up to 100Vrms 141Vpeak Do not expose the transformer to rain or moisture The transformer module must be installed in a safe manner Cloud Electronics Ltd accept no responsibility for hazardou...

Page 2: ...n the host unit s rear panel Speaker Outputs NOTE unlike other Cloud multi channel amplifiers all 46 120 models use a single output connector for both low impedance and 70 100V line operation Thus it is NOT possible for any channel of a 46 120 to drive both low impedance speakers and 70 100V line systems simultaneously The check boxes below the connector should be used to indicate the standard eac...

Page 3: ...and the screw head should be on the outside of the chassis If fitting fewer than four CXL 46Ts any of the fixing positions may be used Orient the transformers so that the flying leads face the rear of the chassis 4 For the zone being converted to 70 100V line operation unplug the relevant 4 pin female connector from its ZONE O P socket on the main PCB immediately behind the rear panel SPEAKER OUTP...

Page 4: ...diagram on previous page 7 If configuring the zone output for 70V line operation plug the transformer s other flying lead blue mauve white into the ZONE O P connector vacated in Step 4 8 For each zone being converted to 70 100V line operation enable the channel s 65 Hz hi pass filter by moving the appropriate jumper from OFF to ON these are J3 Zone 1 J4 Zone 2 J8 Zone 3 and J9 Zone 4 This is impor...

Page 5: ...F England Tel 44 0 114 244 7051 Fax 44 0 114 242 5462 email info cloud co uk web www cloud co uk Cloud Electronics USA 1200 Iron Horse Drive Unit A Park City Utah 84060 United States of America Toll Free 0855 810 0161 email sales cloudusa pro web www cloudusa pro ...

Reviews: