23
ANT4: the reading times of NO.4 antenna
RSSI:Signal Intensity
4.5.2.1 Read EPC
Click the button
, the data display area will display the current read EPC data
EPC display as hexadecimal character string, use the word as length unit (1 word = 2 bytes = 4
hexadecimal character)
If you want to read the EPC data of the custom length, please refer to chapter 4.5.2.3 custom read
4.5.2.2 Read TID
Click the button
, the data display area will display the current read EPC and TID data
TID data display as hexadecimal character string, use the word as length unit (1 word = 2 bytes = 4
hexadecimal character).
TID length, the default is 6 words.
If you want to read the TID data of the custom length, please refer to chapter 4.5.2.3 custom read
4.5.2.3 Custom read
Click the button
, pop-up dialog box, as shown in Image 4-13
Select "6C tag configuration"
Matching read, you can matching read through known EPC data or TID data of tags.
Read TID, select to read the tag TID data, the read mode default as "adaptation", use the word as
length unit.
Read the user area, select to read the tag user area data, use the word as the starting address and
read length unit
Read the reserved area, select to read the tag retains data, use the word as the starting address and
read length unit