background image

                                                                                                               

  CL7206B  user  manual 

32 

 

Image 4-15 write EPC data 

Select a label data (contains TID information) has been read, fill in the EPC data (16 hex string), 

click "OK". 

4.5.3.2 Write user data 

Click button 

  and pop up dialog box as shown in image 4-16: 

Summary of Contents for CL7206B

Page 1: ...1 54 User Manual of CL7206B RFID Reader Shenzhen Clou IOT Technologies Co Ltd Demo software V2 0 2 V2 0 9...

Page 2: ...2 54 Welcome to be user of CLOU RFID products Thanks for choosing CLOU s integrated RFID Reader CL7206B We believe our device will bring convenience for your work...

Page 3: ...9 2 3 2 I O aviation port chart 10 2 3 3 LED panel description 11 2 4 External cable connection description 12 2 4 1 Power supply communication cable description 12 2 4 2 I O control interface cable d...

Page 4: ...er performance 21 4 Software operating 23 4 1 Demo software 23 4 2 Application environment 23 4 3 Software version 23 4 4 Installation 23 4 5 Operation 24 4 5 1 Device connection 24 4 5 2 Data display...

Page 5: ...I O configuration 43 4 5 14 Others 44 4 5 15 Tools 46 5 Common failures 49 5 1 Daily maintenance 49 5 2 Common failure analysis and solution 49 6 Package 51 6 1 Package 51 6 2 Accessories 51 6 3 Stora...

Page 6: ...sensitivity strong anti interference etc 1 2 Technical 1 2 1 Main function Protocol support ISO18000 6C 6B standard Built in LINUX operating system Multiple communication port Ethernet RS232 RS485 USB...

Page 7: ...rcular antenna VSWR 1 4 1 Integrated circular antenna gain 9dBi RS232 serial communication rate 115200bps default 19200 bps 9600bps RS485 interface communication rate 115200bps default 19200 bps 9600b...

Page 8: ...on Physical size 290mm 290mm 115mm accessories not included Image 2 1 Structure diagram 2 2 Weight Main body 5kg accessories excluded 2 3 Interface chart Image2 2 I O communication interface 1 power c...

Page 9: ...munication port aviation port number chart Aviation plug signal definitions Chart 2 1 Power communication interface signal definition PIN Description PIN definition 9 Power supply GND PGND 8 Power sup...

Page 10: ...iving RXD RX 10 RS232 receiving RXD TX Picture2 4 I O interface aviation port number chart 2 3 2 I O aviation port chart I O aviation port definition as per in chart 2 2 Chart 2 2 I O port signal func...

Page 11: ...t cathode IGND 2 Wiegand output 0 WG0 1 Wiegand output 1 WG1 14 GND AGND 13 RS485 signal 485 12 RS485 signal 485 11 GND AGND 10 GND AGND 2 3 3 LED panel description Picture 2 5 LED panel chart LED pan...

Page 12: ...ng net 14 shares inner core outer diameter 7 8mm main cable length is 4m branch cables length are 1m As shown in below picture the aviation plug connected with the reader Power and communication inter...

Page 13: ...ed with reader I O control interface 14 core lines mainly provides two way optical coupling input port two way relay control ports two Wiegand output two way communication port 485 Mainly used for inp...

Page 14: ...lor of the cable Chart 2 4 I O control aviation seat definition table PIN description Marking number Relay 1 output port 9 Relay 1 output port 8 Relay 2 output port 7 Relay 2 output port 6 Optocoupler...

Page 15: ...cable length within 5meters impedance 50 the insertion loss less than 2dB Of course you can choose a high performance cable appropriately increase the length but keep the insertion loss less than 2dB...

Page 16: ...mpedance 50 Ohms Weight 2 3lbs Mechanical size 10 2 x 10 2 x 1 32 Antenna Connection coax pigtail Rev INC Males Working temperature 25 70 Lightning protection DC grounded Environmental rating IP65 2 4...

Page 17: ...CL7206B user manual 17 Image 2 12 Network application connection diagram...

Page 18: ...nected with ground 3 pay attention to the network cable and serial cable type selection and length restrictions 4 When installing multiple readers pay attention to reader antenna display way the minim...

Page 19: ...uation the reader antenna angle should be adjusted to the best condition till when the reading performance reaches its best after testing 3 3 2 Connected with PC RS 232 interface is used for short ran...

Page 20: ...lts and two toothed installation bracket to fix the reader on vertical rod through the L bracket As per illustrated in picture 5 2 Note This installation method is suitable for 50mm 100mm diameter ver...

Page 21: ...vertical rod through the L bracket As per illustrated in picture 5 3 Note This installation method is suitable for 50mm 100mm diameter horizontal pole Picture 3 3 Horizontal pole installation 3 6 Acc...

Page 22: ...CL7206B user manual 22 check confirm the reader is working normally check confirm the reading range is set properly...

Page 23: ...nna ANT1 ANT2 is built in antenna 3 If the reader and writer start up hear drop buzzer sound 4 2 Application environment The software environment Windows 2000 Service Pack 3 Windows Server 2003 Window...

Page 24: ...click the icon to start the Demo software the main interface of the toolbar icons are gray means reader is not connected in the connecting reader option list select communication mode serial connectio...

Page 25: ...o the router through cable and switcher router or connected with the PC network port directly Select the communication mode TCP connection in the connect reader option list connect parameter input rea...

Page 26: ...9 Note The IP address of the reader can t be repeated Use the Ping command to test whether the network is connected on PC image 4 9 reader configuration 4 5 1 3 RS485 communication connection Select t...

Page 27: ...elect the communication mode serial port in the connect reader option list connect parameter select COM the USB serial number detected by PC the communication rate is selected 115200 the default value...

Page 28: ...n be read and written Reserve Data reserved area data store the password data etc Total Count total number of tags ANT1 the reading times of external antenna ANT2 the reading times of built in antenna...

Page 29: ...TID data of the custom length please refer to chapter 4 5 2 3 custom read 4 5 2 3 Custom read Click the button pop up dialog box as shown in Image 4 13 Select 6C tag configuration Matching read you c...

Page 30: ...om configurations Select the 6B tag configuration and pop up dialog box as shown in image 4 14 Can choose to read TID data or user data Can matching read TID data Tip Customer who not familiar with th...

Page 31: ...manual 31 Image 4 14 6B Tag custom configurations 4 5 2 4 Stop read Click button stop all read and write operations 4 5 3 Write data 4 5 3 1 Write EPC data Click button and pop up dialog box as shown...

Page 32: ...al 32 Image 4 15 write EPC data Select a label data contains TID information has been read fill in the EPC data 16 hex string click OK 4 5 3 2 Write user data Click button and pop up dialog box as sho...

Page 33: ...33 Image 4 16 write user data Select a label data contains TID information has been read fill in the user data 16 hex string click OK 4 5 3 3 Custom tag action Click button and pop up dialog box as s...

Page 34: ...d 2 Click the custom operation button 3 Take detailed action to write lock destroy tag according to the reader protocol 4 5 4 TCP server client mode Select configuration on the main demo interface rea...

Page 35: ...a server mode the connection is initiated by PC when the reader set as a client mode it will connect to the PC side automatically 4 5 5 Antenna configuration Select configuration on the DEMO main inte...

Page 36: ...means configure succeeds If the antenna enable is not selected when select the corresponding reader on the DEMO main interface will pop up dialogue box as shown in image 4 20 Image 4 20 Antenna selec...

Page 37: ...PC base band rate provides five options Tair 25us FM0 LHF 40KHz dense reading mode Tair 25us Miller4 LHF 300KHz fast reading mode 255 OUTO Session four choices 0 1 2 3 Q values provide sixteen options...

Page 38: ...ion of the success of the dialog box click OK to complete power configuration 4 5 8 Clock setting Select configuration on the DEMO main interface senior reader configuration then pop up dialog box as...

Page 39: ...frequency hopping management dialog box as shown in image 4 24 Imag 4 24 Frequency Hopping management Select CMII 920 925MHz see Image 4 25 in the working band drop down list click the Settings selec...

Page 40: ...cleared Image 4 25 Frequency Band selection Note The purpose of setting up the automatic is to avoid the interference of the external signal and select the fast frequency hopping The default configur...

Page 41: ...der s complete collection of rfid tags data CL7206C4 support tag data caching mechanism and breakpoint resume in case that the tag s data loss because of the communication interrupted or PC applicatio...

Page 42: ...int resume mode PC will confirm to each tag data from reader under mass quantity of tag data will reduce the communication efficiency increase the system load we suggest When start the breakpoint uplo...

Page 43: ...omatically enter a period of idle state to save power consumption the reader re enter the card reader automatically after idle time 4 5 13 GPI O configuration GPI O control is to provide the query and...

Page 44: ...Description when the start condition is satisfied the reader will perform the configuration of the reader writer command GPO configuration Select configuration on the main interface GPI O configurati...

Page 45: ...Parameter configuration includes Weigand 26 Weigand 34 and Weigand 66 models Weigand 26 TID or EPC data reported from the end of the Weigand port is valid for 3 bytes Weigand 34 TID or EPC data report...

Page 46: ...the reader will be restored to the factory setting 4 5 15 Tools Data export Select tools on the main interface data export form XLS in the pop up dialog box as shown in image 4 32 select the required...

Page 47: ...tions Select tools on the main interface software upgrade software the pop up dialog box as shown in image 4 33 Image 4 33 Application software upgrade To find the Bin upgrade file path in the upgrade...

Page 48: ...CL7206B user manual 48 Image 4 34 Software upgrade successfully The process of the application of the base band software is the same as that of the application software...

Page 49: ...240V The panel indicator light failed when power on Check whether the communication is normal please contact customer service if it s not normal The serial port unable to connect Check if the serial c...

Page 50: ...nna number is correct Check if the label is damaged Check if the label is placed in the reader s valid reading and writing range Check if the electromagnetic interference between the reader and the ot...

Page 51: ...box and the packing material should be kept properly after unpack Besides of the device in the box accessories equipped with the reader are also included in please check the product packing list to c...

Page 52: ...20351000000551 1 Pcs Included 3 Power adapter 24V 2 5A 20109000000324 1 Pcs Included 4 AC power cable 20350000000195 1 Pcs Included 5 Network cable 20350000000188 1 Pcs Included 6 RS232 connection ca...

Page 53: ...uct characteristics composition and design of circuits without given notifications Thus the real product may be not in accordance with this manual Generally we will provide timely amendments to this m...

Page 54: ...in the precondition of normal operation without repairing 2 Free maintenance won t be given under the following circumstance The damage of the terminal caused by high voltage of the power grid The da...

Reviews: