housing, use four hexagon socket head cap screws GB70-85 M5 * 12 for tightening. Refer
to picture in 5-3:
2>Using two U-bolts and two toothed installation bracket to fix the reader on vertical
rod through the L-bracket. As per illustrated in picture 5-3.
Note: This installation method is suitable for 50mm ~ 100mm diameter horizontal pole.
Picture 3-3 Horizontal pole installation
3.6 Acceptance
3.6.1 Check physical installation
1> Check & ensure the reader is fixed safely;
2> Check & ensure cables are connected securely.
3> Check & ensure screws are screwed firmly.
3.6.2 Check reader performance