background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for SmartHub-FT

Page 1: ......

Page 2: ...temperature recording technology The facial sensor has a quick matching speed high resolution and can be operated touchless Using Infrared technology an abnormal temperature can be identified immediately The guidelines within this document must be adhered to upon installing the SmartHub FT ...

Page 3: ...xceptions being generated Power Outlet Cables It is recommended where possible the power outlet is installed at high level 2 0m 2 2m to avoid the possibility of damage or tampering We would also recommend that a tamper proof cover is place over the power outlet The power outlet should be no more than 1 5m linear line of cable route not direct away from the location of the device Environment Recomm...

Page 4: ...pyright of all content contained in this guide Without our company s permission the content shall not be reproduced modified or used in any form As the product is updated regularly we cannot guarantee the consistency of the actual product with the contents of the manual Our company is not responsible for any disputes and liabilities caused by the differences between the actual technical parameters...

Page 5: ...temperature measurement accuracy of the equipment please follow the following requirements Equipment installation indoor environment The equipment should not be directly facing the air conditioner and fan avoid direct sunlight and require no obvious rapid temperature change environment ...

Page 6: ... accuracy During temperature measurement do not move the forehead position to avoid temperature change caused by forehead position change Make sure there is no cover on the forehead hat hair and no sweat on the forehead when doing temperature measure Don t cover your forehead with cold water or warm water before measurement When measuring temperature avoid temporarily putting down or taking off yo...

Page 7: ...nect to the wiring terminals Plug the wiring terminals into the device and use four supplied M5 screws to secure the bracket on the device Align the device with the mounting plate and buckle them together and use two supplied M3 screws to secure the device on the mounting plate Adjust the tilt angle of the device according to your actual needs Height And Angle ...

Page 8: ...Cable Connection ...

Page 9: ...ure Measurement In order to guarantee the accuracy of temperature detection the temperature measurement area is the forehead area 3 3 Cautions for Temperature Measurement To ensure the exact measuring area for forehead position is required to be on the right place of the face frame on the TPS980 LCD when measuring temperature DO NOT move your forehead when measuring temperature Ensure there is no ...

Page 10: ...hernet WiFi Bluetooth LTE GPRS Sensor Infrared Sensor Body Temperature Measurement Precision 0 3 C best use distance of 0 7m 1m from device Camera Front Dual lens Camera RGB IR 2MP 1 3MP Fill Light White LED Peripheral Ports 1 DC Port 1 RJ45 1 micro USB 1 Wiegand 1 RS485 Keys 1 Reset Key Audio Digital Audio Speaker Microphone NFC Reader ISO14443 Type A B Mifare ISO18092 compliant Power Supply 12V ...

Page 11: ...IP Rating IP64 Totally protected against dust Protected against water splashed from all directions limited ingress permitted Certification CE ...

Reviews: