Controls and Connectors
On both sides of the CCRM 4000 there are controls and connectors.
Description
Connector
Power
Two +18VDC power connectors are provided. One can
be used for power In, while the other can be used to
distribute power to the next daisy chained unit.
Using Clockaudio recommended PSU, up to 4 CCRM
4000s can be daisy-chained.
Impedance matching “Z”
On each of the units is a slide switch “Z”. In a
multi-unit system of 2 or more units, it is only the final
Secondary unit that needs to have this switch ON and
all other units’ switches must be OFF.