6
4
Sound levels
Standard mode
General technical data
Size
Sound power level
Sound
pressure
level
Sound
power
level
Octave band (Hz)
63
125
250
500
1000 2000 4000 8000
dB(A)
dB(A)
18.2
62
67
68
72
79
72
64
52
64
82
20.2
68
79
76
73
76
67
59
52
65
82
25.2
65
66
69
73
80
73
65
51
62
81
30.2
59
67
69
72
80
73
65
51
65
84
35.2
87
77
76
76
79
68
60
53
67
85
Silenced mode
Size
Sound power level
Sound
pressure
level
Sound
power
level
Octave band (Hz)
63
125
250
500
1000 2000 4000 8000
dB(A)
dB(A)
18.2
54
57
62
67
66
64
57
46
56
74
20.2
73
65
70
69
65
62
55
49
56
74
25.2
66
57
60
68
67
65
56
43
58
76
30.2
61
55
59
67
66
63
55
41
58
76
35.2
86
67
69
70
63
58
54
47
58
76
Silenced mode can be set from the user interface terminal
Super silenced mode
Size
Sound power level
Sound
pressure
level
Sound
power
level
Octave band (Hz)
63
125
250
500
1000 2000 4000 8000
dB(A)
dB(A)
18.2
48
51
57
62
58
61
56
44
52
70
20.2
68
64
70
64
59
62
54
48
53
71
25.2
69
58
59
66
62
59
51
40
53
71
30.2
61
49
56
64
61
59
52
39
53
71
35.2
86
63
58
68
60
56
54
48
55
73
At maximum conditions data
Sound levels refer to units with nominal test
conditions.
The sound pressure level refers to a distance of 1
meter from the outer surface of the unit operating in
open field.
Noise levels are determined using the tensiometric
method (UNI EN ISO 9614-2)
Data referred to the following conditions in cooling:
- internal exchanger water = 12/7°C
- ambient temperature 35°C
Sound levels refer to units with nominal test
conditions.
The sound pressure level refers to a distance of 1
meter from the outer surface of the unit operating
in open field.
Noise levels are determined using the tensiometric
method (UNI EN ISO 9614-2)
Data referred to the following conditions in cooling:
- internal exchanger water = 12/7°C
- ambient temperature 35°C
Sound levels refer to units with nominal test
conditions.
The sound pressure level refers to a distance of 1
meter from the outer surface of the unit operating
in open field.
Noise levels are determined using the tensiometric
method (UNI EN ISO 9614-2)
Data referred to the following conditions in cooling:
- internal exchanger water = 12/7°C
- ambient temperature 35°C
Super Silenced mode can be set from the user interface terminal
Size
Sound power level
Sound
pressure
level
Sound
power
level
Octave band (Hz)
63
125
250
500
1000 2000 4000 8000
dB(A)
dB(A)
18.2
55
65
67
72
77
70
61
50
67
83
20.2
55
65
67
72
77
70
61
50
67
83
25.2
57
67
69
73
79
72
64
51
69
85
30.2
57
67
69
73
79
72
64
51
69
85
35.2
57
67
69
73
79
72
64
51
69
85
Sound levels refer to units with nominal test
conditions.
The sound pressure level refers to a distance of 1
meter from the outer surface of the unit operating
in open field.
Noise levels are determined using the tensiometric
method (UNI EN ISO 9614-2)