DOMESTIC HOT WATER
Information displayed:
•
upper storage temperature
•
lower storage temperature
•
solar water temperature
DOMESTIC HOT WATER OPERATION
2 - Automatic operation:
domestic hot water is produced automatically, according to the
requirement, using all the resources available.
3 - With thermal solar system only:
the storage tank temperature is ensured only using solar collectors,
even with a greater set point.
4 - With auxiliary heating only:
the storage tank temperature is maintained only using the auxiliary
heater (heater or integrated boiler).
5 - Deactivates the production:
excludes the production of domestic hot water.
In this mode, the temperature of the storage tank is not controlled.
Confirm the modification
1
2
3
4
5
6
7
8
9
10
11
select
1
select
6
DOMESTIC HOT WATER PROGRAMMING
Elfocontrol
2
is equipped with 3 preset time schedules.
Up to 7 programs can be saved in the memory.
All programs can be modified.
12
select
12
DOMESTIC HOT WATER SETTINGS
7 - Water set point with heat pump
is indicated as RELOAD in the programming
8 - Water set point with heat pump
is indicated as MAINTENANCE in the programming
9 - Maximum temperature allowed with solar collector
10 - Minimum temperature difference to activate the solar collector: the
solar collector activates when the temperature is 15°C
higher than the storage tank
11 - Activates the circulation for 3 minutes every 60 minutes
The
recirculation
function prevents the stratification in the ACS
accumulation.
Is active only at the times foreseen by the scheduler (Maintenance
+ recirculation, Re recirculation).