25
1.5
COMBUSTION CHAMBER
The combustion chamber is of the
straight flow type and complies with
standard EN 303-3 appendix E.
The dimensions are shown in fig. 3.
1.6
COMPATIBLE BURNERS
In general, the oil burner that is compa-
tible with the boiler should use spray of
the semi solid type.
Sections 1.6.1 - 1.6.2 shows the matching
table of the burners together with the
boilers have been tested with.
1.6.3 Burners assembly
The boiler door details is shown in figure
4 for burner mounting.
The burners must be regulated such that
the CO
2
value is that indicated in point
Fig. 3
L
Volumen
mm
dm
3
GG E 3
305
17,5
GG E 4
405
24,0
GG E 5
505
30,5
GG E 6
605
37,0
GG E 7
705
43,5
R 75
ø 110
M8
Fig. 4
1.6.1 “RIELLO” burners
1.6.2 “CLIMIT” burners - NOx: Class 3 (Burner with low polluting emissions)
Model
Nozzle
Atomising
Pump pressure
Type
P min
P max
angle
P min
P max
ø
ø
P min
P max
bar
bar
GG E 3
RG0.1R
DELAVAN
0,50
0,60
60°W
60°W
11,5
12,0
R2000 G26 R
DANFOSS
0,50
0,55
60°S
60°S
10,5
12,0
GG E 4
RG1R
DELAVAN
0,65
0,75
80°W
60°W
12,5
13,0
R2000 G38 R
DELAVAN
0,60
0,75
80°W
60°W
13,0
12,5
GG E 5
RG1R
DELAVAN
0,85
1,00
60°W
60°W
11,5
11,5
R2000 G46 R
DELAVAN
0,75
0,85
80°W
60°W
13,9
14,0
GG E 6
RG2
DELAVAN
1,00
1,10
60°W
60°W
10,0
10,0
R2000 G120
DELAVAN
1,10
60°W
12,0
GG E 7
RG2
DELAVAN
1,10
1,25
60°W
60°W
11,0
11,0
R2000 G120
DELAVAN
1,25
60°W
13,0
Model
Nozzle
Atomising
Pump pressure
Type
P min
P max
angle
P min
P max
ø
ø
P min
P max
bar
bar
GG E 3
BLUE MACK 1 LC DANFOSS
0,50
0,50
80°H
80°H
12,0
12,0
GG E 4
BLUE MACK 1 LC DANFOSS
0,65
0,65
60°S
60°S
12,0
12,0
GG E 5
BLUE MACK 2 LC DANFOSS
0,75
0,75
60°H
60°H
12,0
12,0
GG E 6
BLUE MACK 2 LC DANFOSS
1,10
1,10
60°H
60°H
12,0
12,0
GG E 7
BLUE MACK 3
DANFOSS
1,25
1,25
60°S
60°S
10,0
12,8
NOTE: The best emission values are obtained with Danfoss 60°H nozzles. Use of Danfoss 60°H nozzles is recommended in the field to
ensure continued dependable burner functioning.
Summary of Contents for GG E 3
Page 1: ...GG E 3 7 Cod 6276052A 07 2019 IT ES ENG FR RUS ...
Page 5: ...3 1 4 PERDITE DI CARICO CIRCUITO CALDAIA Fig 2 GG E 7 GG E 6 GG E 5 GG E 4 GG E 3 ...
Page 12: ...10 NOTE ...
Page 26: ...24 1 4 LOSS OF HEAD Fig 2 Loss of head mbar Flow l h GG E 7 GG E 6 GG E 5 GG E 4 GG E 3 ...
Page 36: ...24 1 4 LOSS OF HEAD Fig 2 Loss of head mbar Flow l h GG E 7 GG E 6 GG E 5 GG E 4 GG E 3 ...
Page 63: ...51 NOTE ...
Page 64: ...52 NOTE ...
Page 65: ......
Page 66: ...Via Garbo 27 37045 Legnago Vr Tel 39 0442 631111 Fax 39 0442 631292 ...