11
CTK 240 mobile air dehumidifier
The following notes must also be
observed in full:
•
Ensure that the air can discharge
without hindrances
This is the only way to
guarantee optimum unit
operation!
•
Ensure that sensitive objects
such as house plants are not
placed directly in the air flow
emerging from the unit.
Automatic defrost system
The moisture contained in the
room air condenses when cooling
and coats the evaporator fins with
rime or ice depending on the
air temperature and the relative
humidity (% RH).
The automatic defrost system that is
integrated in the unit switches the
defrost cycle on if required.
The rime or ice that has
accumulated on the exchanger
surfaces is defrosted using
electronic circulation mode as
required.
This tried and tested defrosting
method guarantees high
dehumidification performance.
Dehumidification mode is paused
during the defrost phase.
The “Defrost mode” indicator light
indicates that the defrost cycle is
running.
The higher the room temperature
and relative air humidity, the higher
the dehumidification power.
A relative humidity of around
45 to 60 % is sufficient in living
rooms. The air humidity should not
exceed 40 to 45 % in
warehouses, archives, etc.
Timer function
The units feature an integrated
timer function.
Pressing the timer key switches the
unit’s automatic mode on and off.
If automatic mode is switched off,
the arrow keys can be used to set
the required operating time.
The operating time can be set for a
maximum of 24 hours in increments
of an hour.
The unit will switch itself off
automatically after the set time has
elapsed.
NOTE
If the room temperature is
sufficiently high (>12 °C), the
surface of the fins will not be
cold enough for rime formation
to occur, rendering defrosting
unnecessary.
Therefore, the air dehumidifier
works economically.
Emptying the condensate
container
The integrated condensate
container must be emptied from
time to time.
Dehumidification mode is switched
off if the condensate container is
full.
The “BUCKET FULL” indicator light
indicates that the unit has switched
off.
1. Pull the full container forwards
and out carefully.
2. Pour the water into a drain.
3. Re-insert the emptied container
carefully into the unit.
The “BUCKET FULL” indicator light
extinguishes and the unit continues
to run automatically.
NOTE
For economical and technical
reasons, the units must not
be operated at an ambient
temperature below 5 °C.
NOTE
After being emptied, the
condensate container incl. float
must be checked for damage,
contamination etc.
NOTE
The unit can only be started once
the condensate container has
been inserted correctly.
NOTE
The devices can be switched ON
and OFF via an external timer or
a Smart Home socket if required.
Summary of Contents for CTK 240
Page 1: ...CLIMIA CTK 240 mobile air dehumidifier Operating manual Edition 1 0 English ...
Page 2: ......
Page 21: ...21 CTK 240 mobile air dehumidifier Notes ...
Page 22: ...22 CLIMIA ...
Page 23: ...23 CTK 240 mobile air dehumidifier ...
Page 24: ...Intakt GmbH Climia Klima und Wärmetechnik Niemeierstraße 13 D 32758 Detmold ...