Local room air conditioner CMK 2600
The unit does not operate, the
control panel remains dark
•
Ensure,
· that the power plug is properly
plugged in.
· that there is no power failure.
· that the mains power is present
(fuse/breaker).
•
Check the power supply cable
for damage.
The unit does not work, LED
indicator "Timer" illuminates
The "Timer" time delay is
programmed if a green LED is
illuminated in the right hand corner
of the display underneath the
temperature display. Deactivate the
timer function.
The unit does not operate,
... the display shows "EC"
•
No cooling capacity after
30 minutes. Possible lack of
refrigerant, contact your dealer.
... the display shows "E1"
•
Recirculation temperature probe
faulty
... the display shows "E2"
•
Suction pipe (pipe contact
sensor) temperature probe faulty
... the display shows "E4"
•
Communication error between
display and control board
... the display shows "P1"
•
The unit's condensate collection
tray is full.
Proceed as follows to empty the
reservoir:
1. Switch unit off, pull out power
plug.
2. Place a shallow container
underneath the drain outlet and
loosen the stopper.
3. After the condensate has drained
off, plug the stopper back in
again firmly.
4. Switch the unit back on.
Is the fault still present?
Contact your dealer.
The unit does not cool properly
•
Check the operating mode:
The "Cool" LED indicator on the
LCD must illuminate.
•
For optimum cooling capacity,
you should close curtains and
blinds. Also, ensure that windows
and doors are closed.
•
Ensure that the exhaust air hose
is properly attached.
It must not be kinked, sloping
downwards or laid in bends that
are too tight.
... that there are no foreign
bodies impairing the air supply
or air exhaust (observe minimum
clearance).
... that the ventilation louvres are
free of dirt and foreign objects.
... that the target temperature is
not set too high (unit operating
range 17 to 35 °C).
The unit does not respond to
the remote control
•
Ensure that the batteries are in
good working order, otherwise
replace the batteries.
... that the batteries have been
inserted with the correct polarity
(see markings).
... that there are no objects
between the remote control and
the unit (range ca. 5 m).
The unit and components are manufactured using state-of-the-art production methods and tested several times to
verify that they function correctly. If malfunctions should occur, please check the unit as detailed in the list below.
Please inform your dealer if the unit is still not working correctly after all the function checks have been performed.
14.0 Troubleshooting and customer service
CAUTION!
Never open the
unit housing.
CAUTION!
Never carry out work on
the cooling cycle or on the
electrical equipment.
NOTE
Contact your dealer or
contractual partner if the unit
cannot be activated.
13
Summary of Contents for CMK 2600
Page 1: ...Edition 3 0 English CLIMIA Local room air conditioner CMK 2600 Operating manual ...
Page 2: ...CLIMIA ...
Page 14: ...15 0 Electrical wiring diagram Fig 12 Connection diagram CMK 2600 CLIMIA 14 ...
Page 19: ......
Page 20: ...Intakt GmbH Climia Klima und Wärmetechnik Niemeierstraße 13 D 32758 Detmold ...