19/28
2015/12 - Indice de révision : B - Code : 33491
Dimensions and technical data
(1) : the dehumidification capacity refers to the volume of condensates recovered in one day at a constant
temperature of 30°C and relative humidity of 70%.
(2) : ambient temperature 30°C, relative humidity 70%.
Technical data is susceptible to modification to reflect product upgrades.
Dimension
(mm)
Ref
Model
A
B
C
D
E
F
G
H
DH60
286
886
200
126
613
718
36
860
DH90
286
1186 200
126
913
718
36
860
DH120
286
1186 200
126
913
718
36
860
Technical data
DH60
DH90
DH120
Dehumidification capacity (1) litres/24h
60
93
120
Nominal input power (dehumidification mode) W
990
1690
2000
Maximum input power (dehumidification mode) W
1200
2000
2450
Heating power output in dehumidification mode (2) W
2200
4200
5500
Power of the auxiliary heating element (option) W
2000
3000
3000
Air flow rate, fan at full speed m3/h
800
1000
1200
Power supply
monophasé 230 V~50Hz
Nominal/ maximum current (without auxiliary element) A
4,58 / 5,20
7,83 / 9,15
9,15 /
10,8
Accoustic pressure at 5 metres (dB(A))
39,5
40,8
40,8
Net weight/ gross weight (without auxiliary heating) kg
53 / 68
70 / 86
75 / 91
Quantity of refrigerant R 410 A g
800
1050
1300
Overall dimensions (length*width*height)
855x242x848
1155x280x848