Connect the
Dorsal D-Ring Connector
directly to the Dorsal D-Ring of a compatible
full body harness. This is the only permitted
connection for the Dorsal D-Ring Connector.
D-Ring extensions or other products that
may increase the length of this connecting
subsystem are strictly prohibited.
CLEANING AND LUBRICATION INSTRUCTIONS
1. With safety depressed and gate in unlocked
position, use compressed air to expel dirt from
gate. Pay particular attention to locations shown.
2. Repeat step 1 using a PTFE based Dry Lubricant
with no harsh chemicals (DuPont Teflon Non-stick
Dry-Film Lubricant Model DNS616601 or
equivalent).
3. Repeat steps 1 and 2 as necessary, then dry with
compressed air and remove excess lubricant with a
dry cloth.
ENERGY ABSORBING LANYARD CONNECTION INSTRUCTIONS
Cleaning periodically will prolong the life and proper functioning of the product. The
frequency of cleaning should be determined by inspection and by severity of the
environment. Clean with a mild soap and warm water solution. Do not use any corrosive
chemicals that could damage the product. Wipe all surfaces with a clean, dry cloth to
remove excess water and hang to dry. When not in use, store in a cool, dry, clean
environment, out of direct sunlight and free of corrosive or other degrading elements.
MAINTENANCE, CLEANING AND STORAGE
Summary of Contents for EAL12NC-72Y-C13