To: Next Module
From: Previous Module
Main
N
MODE
Circut
Breaker
MODE
Circut
Breaker
MODE
Circut
Breaker
MODE
Circut
Breaker
MODE
Circut
Breaker
MODE
Circut
Breaker
MODE
Circut
Breaker
MODE
Circut
Breaker
1
2
3
4
5
6
7
8
9
10
11
12
13 14
15
15 16
Com
1-4
Com
5-8
Com
9-12
Com
13-16
5
7
6
8
Before wiring the device, always unplug the main power.
Follow this wiring to setup the module.
Follow the diagram below to apply appropriate output/input and protect module in case of
unwanted short circuit.
Enable/disable Autosave
If autosave func on is ac vated, reconnec ng main power will set all outputs to the last status
(before power outage).
In order to enable/disable autosave follow steps below consecu vely and uninterruptedly:
1. Disconnect the main power. Hold bu on #1 & #2 simultaneously (bu on’s and LED’s number
sequence is considered from right to le as shown in page 4)
.
2. Reconnect the main power. Release bu on #2 a er LEDs #1 to #4 flashed. Then release bu on
#1 a er LEDs #1 and #2 flashed. Power LED will start flashing quickly.
3. Press bu on #2, 4 mes.
4. To disable/enable autosave mode, press bu on #1. LED #1 will display whether autosave mode is
disabled or enabled. If it is “on” the autosave mode is enable.
5. Press bu on #3 to save new se ng and bu on #4 to cancel.
It is recommended to disable autosave unless it is needed to be enabled.
Use one 10A fuse for every four channel.
Module’s LEDs
Power:
“Power LED” will flash smoothly.
When the module is connected to main power,
Status:
“Status
When the module is connected to C-Bus network and receives valid data packets,
LED” flashes quickly. “Status LED” is “of” when the module doesn’t receive any data.
When the module is receiving invalid data packet, “Status LED” will remain “on” for 5 seconds.
In some cases, when a new module is added to C-Bus network,
all Status LEDs might remain
“on”
for 5 seconds. This situa on must not be considered as an error.
Ch1 to Ch16: Shows the status of module’s relays. Also when the module is connected to main
power, the channel LEDs will display the module address in binary for 2 seconds.
Toggle Module’s Channels
Ch1 to Ch8:
For toggling Ch1 to 8 press and hold bu ons 1# to 8# for less than 700 ms.
Ch9 to Ch16:
For toggling Ch9 to 16 press and hold bu ons 1# to 8# for more than 700 ms. For
instance to toggle Ch14, press
#6 for more than 700 ms.
and hold bu on
Ch9
Ch10
Ch11
Ch12
Ch13
Ch14
Ch15
Ch16
C-Bus
C-Bus
#2
#3
#4
#5
#8
#1
#6
#7
Use the terminator socket for the last module in C-Bus network.